background image

 

Installing The Cable

 

The SuperStack II Advanced RPS and its modules 

 

may be hot-connected to SuperStack II units.

 

Connecting Cables

 

Before attaching the cables, check that the power 

 

demand of the product does not exceed the 

 

capacity of the Power Module you are connecting. 

 

This information is given in the Power Module user 

 

guide (DUA1607-2AAA0X), your Advanced RPS 

 

Chassis user guide (part number DUA1607-0AAA0X) 

 

and the product user guide. If you are unable to 

 

find the information or are unsure, please contact 

 

your supplier.

 

When mating the special RPS connectors 

 

to the inlet and outlet sockets, take care to 

 

ensure that the retaining spring, where 

 

fitted, locates outside the plug casing.

 

Redundancy

 

Use a standard DC cable (as supplied with your 

 

power module) to provide managed redundancy 

 

connecting the outlet of the power module to the 

 

inlet of the product. The product you are 

 

connecting must be one with the auto-enable 

 

feature present for this redundancy.

 

Full Redundancy

 

Use the ‘Y’ cable to provide full redundancy 

 

(resilience) connecting one short lead to each of 

 

two module outlets on the RPS and the long lead to 

 

the product inlet. 

 

After installing the cable, this guide should be 

 

stored with your other 3Com user guides.

 

Fault Diagnosis

 

The LEDs on the front of the Advanced RPS Chassis 

 

provide simple at-a-glance fault diagnosis of the 

 

installed Power Modules.

 

If you suspect a problem:

 

Check that you have allowed at least five 

 

seconds for the Power Module to warm up.

 

Check the status of the LEDs on the front panel 

 

of the chassis, as described in the SuperStack II 

 

Advanced RPS User Guide, part number 

 

DUA1607-0AAA0X. 

 

Ensure the Power Module is correctly installed 

 

in the Chassis.

 

Check  the RPS cables are correctly engaged 

 

and locked.

 

If you cannot rectify the fault, contact your supplier, 

 

giving the following information:

 

the product number.

 

the Power Module serial number.

 

a brief description of the fault.

 

Your supplier will advise you on your next course of 

 

action.

 

DISCLAIMER

 

Information in this document is subject to change without notice and 

 

does not represent a commitment on the part of 3Com Ireland. 3Com 

 

Ireland reserves the right to revise or change this document without 

 

obligation of 3Com Ireland to notify any person of the revisions or 

 

changes. Information contained in this document is believed to be 

 

accurate at the time of publication but no liability whatsoever can be 

 

accepted by 3Com Ireland arising out of any use of this information.

 

This document, or any part of it, must not be copied or reproduced on 

 

any medium without the prior consent of 3Com Ireland.

 

In the unlikely event that this product is found to be damaged on 

 

arrival, or fails to function once installed, you should contact your 

 

distributor or reseller for advice.

 

ACKNOWLEDGEMENTS

 

3Com, SmartAgent and LinkBuilder are registered trademarks of 3Com 

 

Corporation. Registered trademarks are registered in the United 

 

States, and may or may not be registered in other countries.

 

SuperStack is a trademark of 3Com Corporation.

 

Other brand and product names may be registered trademarks or 

 

trademarks of their respective holders.

 

Part Number: DUA1607-9AAA01

 

Revision: 00

 

Issued: February 28th1997

 

© 1997 3Com Ireland

 

A

 

D

 

V

 

A

 

N

 

C

 

E

 

D

 

 RPS ‘Y’ C

 

A

 

B

 

L

 

E

 

 

 

(3C16079)

 

U

 

S

 

E

 

R

 

 G

 

U

 

I

 

D

 

E

 

Introduction

 

The SuperStack II Advanced RPS  (3C16070/1) is 

 

designed to provide redundant power supplies to 

 

the products in 3Com’s SuperStack II range. These 

 

special RPS ‘Y’ cables (3C16079) are required to 

 

connect the DC power to the active units when you 

 

need resilience. This cable allows you to hot-swap a 

 

module while maintaining the power supply to your 

 

network unit.

 

For more general information and  warranty 

 

details for these products, please refer to 

 

SuperStack II Advanced RPS User Guide, 

 

part number DUA1607-0AAA0X. 

 

This guide is written for the installation engineer 

 

and the network administrator who manages and 

 

maintains the network. 

 

Technical Information

 

Physical

 

Length

 

1 metre (39 in)

 

Weight

 

550 g (1.21 lb)

 

Safety Information

 

Please read the following safety information 

 

before installing the cable.

 

Installation of this cable should be carried out by 

 

qualified personnel only

 

.

 

You must not attempt to connect the cable to any 

 

non-RPS power outlet. Damage will result to both 

 

the RPS and the SuperStack II product if you do.

 

L’Information de Sécurité

 

Veullez lire les instructions de sécurité 

 

suivantes avant d’installer le cable.

 

L’ installation du cable doit être faite uniquement par 

 

un personnel qualifé.

 

Vous ne devez en aucun cas connecter le cable à une 

 

entrée non RPS. Il en resulterait des dommages 

 

prejudiciales aux produits RPS et SuperStack II.

 

Sicherheitsinformationen

 

Lesen sie vor Einbau des Kabels die folgende 

 

Sicherheitsinformationen.

 

Der Ein- und Ausbau des Kabels sollte nur durch 

 

Fachpersonal erfolgen.

 

Verbinden sie das Kabel nur mit dem vorgesehenen 

 

RPS Ausgang. Bei nicht Beachtung wird der RPS und 

 

der SuperStack II beshädigt.

i

!

!

!

Reviews: