background image

 

Superseded Products

 

The following superseded products may be powered from 

 

the Advanced RPS. Again their usage is subject to the 

 

total power limitation of 480 watts.

 

Superseded Products requiring a 60 watt 

 

Power Module

 

LinkBuilder Hubs

 

3C215A

 

Hub 100 Management Unit

 

3C250-TX

 

FMS 100 TX 

 

3C16665

 

FMS II Fiber (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16670

 

FMS II 12-port TP (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16671

 

FMS II 24-port TP (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C16672

 

FMS II Telco (also with 3C16630A or 

 

3C16632 Management Module and 

 

3C1206X Transceiver Module fitted)

 

3C510510B

 

FMS TR 12-port 

 

3C510511B

 

FMS TR 24-port 

 

NetBuilder Routers

 

3C8200C

 

NetBuilder Remote Office 200

 

3C8201C

 

NetBuilder Remote Office 201

 

3C8221C

 

NetBuilder Remote Office 221

 

3C8222C

 

NetBuilder Remote Office 222

 

3C8223C

 

NetBuilder Remote Office 223

 

3C8224C

 

NetBuilder Remote Office 224

 

3C8227C

 

NetBuilder Remote Office 227

 

3C8228C

 

NetBuilder Remote Office 228

 

3C8323C

 

NetBuilder Remote Office 323

 

3C8327C

 

NetBuilder Remote Office 327

 

3C8421C

 

NetBuilder Remote Office 421

 

3C8422C

 

NetBuilder Remote Office 422

 

3C8423C

 

NetBuilder Remote Office 423

 

3C8424C

 

NetBuilder Remote Office 424

 

3C8427C

 

NetBuilder Remote Office 427

 

3C8523C

 

NetBuilder Remote Office 523

 

3C8527C

 

NetBuilder Remote Office 527

 

LinkSwitch

 

3C16900

 

LinkSwitch 1000 24-port (also with 

 

3C1206x or 3C16920/2 modules fitted)

 

3C16901

 

LinkSwitch 1000 12-port (also with 

 

3C1206x or 3C16920/2 modules fitted)

 

3C16940

 

LinkSwitch 3000 (also with 3C1206x or 

 

3C16920/2 modules fitted)

 

DISCLAIMER

 

Information in this document is subject to change without notice and 

 

does not represent a commitment on the part of 3Com Ireland. 3Com 

 

Ireland reserves the right to revise or change this document without 

 

obligation of 3Com Ireland to notify any person of the revisions or 

 

changes. Information contained in this document is believed to be 

 

accurate at the time of publication but no liability whatsoever can be 

 

accepted by 3Com Ireland arising out of any use of this information.

 

This document, or any part of it, must not be copied or reproduced on 

 

any medium without the prior consent of 3Com Ireland.

 

In the unlikely event that this product is found to be damaged on 

 

arrival, or fails to function once installed, you should contact your 

 

distributor or reseller for advice.

 

ACKNOWLEDGEMENTS

 

3Com, AccessBuilder, NetBuilder, LinkSwitch and LinkBuilder are 

 

registered trademarks of 3Com Corporation. Registered trademarks 

 

are registered in the United States, and may or may not be registered 

 

in other countries.

 

SuperStack is a trademark of 3Com Corporation.

 

Other brand and product names may be registered trademarks or 

 

trademarks of their respective holders.

 

Part Number: DUA1607-2AAA02

 

Revision: 00

 

Issued:July 11th, 1997

 

© 1997 3Com Technologies

 

3C16941

 

LinkSwitch 3000 TP (also with 3C16920/2 

 

modules fitted)

 

3C32700A

 

Switch 2700 OC-3 Multimode ATM

 

3C32710A

 

Switch 2700 DS-3 ATM

 

3C32711A

 

Switch 2700 OC-3 Singlemode ATM

 

AccessBuilder

 

3C7204

 

AccessBuilder 2204

 

3C7208

 

AccessBuilder 2208

 

LinkConverter

 

3C8252A

 

LinkConverter II 252

 

3C8254A

 

LinkConverter II 254

 

3C8352A

 

LinkConverter II 352

 

Superseded Product requiring a 100 watt 

 

Power Module

 

3C16900

 

LinkSwitch 1000 24-port with 3C16930 

 

module fitted

 

3C16901

 

LinkSwitch 1000 12-port  with 3C16930 

 

module fitted

 

3C16940

 

LinkSwitch 3000  with 3C16930 module 

 

fitted

 

3C16941

 

LinkSwitch 3000 TP  with 3C16930 module 

 

fitted

 

3C32700A

 

Switch 2700 OC-3 Multimode ATM

 

3C32710A

 

Switch 2700 DS-3 ATM

 

3C32711A

 

Switch 2700 OC-3 Singlemode ATM

 

3C220000A

 

LinkSwitch 2200

 

A

 

D

 

V

 

A

 

N

 

C

 

E

 

D

 

 RPS P

 

O

 

W

 

E

 

R

 

 M

 

O

 

D

 

U

 

L

 

E

 

S

 

 

 

(3C16072 & 3C16073)

 

U

 

S

 

E

 

R

 

 G

 

U

 

I

 

D

 

E

 

Introduction

 

The SuperStack™ II Advanced RPS Power Modules are 

 

designed to provide redundant power supplies, from the 

 

SuperStack II Advanced RPS chassis (3C16070/1), to the 

 

products in 3Com’s SuperStack II range. There are two 

 

modules; a 60 watt capacity unit (3C16072) to supply most 

 

of the products and a 100 watt unit (3C16073) for those 

 

products with a higher power requirement. To connect the 

 

power module to the active units, use only the cables 

 

supplied with this module or the special ‘Y’ cables available 

 

from your supplier.

 

For more general information and  warranty details 

 

for these products, please refer to SuperStack II 

 

Advanced RPS User Guide, part number 

 

DUA1607-0AAA0X. 

 

The optional SuperStack II Advanced RPS Management 

 

Module provides management information to a Network 

 

Manager. Details of the management functions are in the 

 

Management Module user guide, part number 

 

DUA1608-0AAA0X.

 

This guide is written for the installation engineer and the 

 

network administrator who manages and maintains the 

 

network. 

 

Safety Information

 

L’Information de Sécurité

 

Sicherheitsinformationen

 

Please read the safety information in the Advanced 

 

RPS Chassis User Guide before installing the module.

 

Veuillez lire les instructions de sécurité dans le 

 

manual d’utilisation du chassis de l’Advanced RPS 

 

avant d’installer le module.

 

Lesen sie vor der Installation des Modules die 

 

Sicherheitsinformationen in der Advanced RPS 

 

Gebrachsanweisung.

 

Power Supply And Fuses

 

All power is supplied and fused from the Advanced RPS 

 

chassis. There are no user-replaceable fuses on the Power 

 

Modules.

 

Installing The Module

 

Power Module Usage

 

You must not connect units with a total power require- 

 

ment of more than 480 watts to any one chassis. 

 

Single Power Modules must be considered as supplying 

 

their rated power.

 

Each Power Module in the full redundancy configuration 

 

may be considered as supplying half its rated power.

 

The SuperStack II Advanced RPS Power Modules may be 

 

hot-inserted into the chassis.

 

It is important that the Power Modules are 

 

cooled effectively. We strongly recommend 

 

installing the Power Modules as evenly as 

 

possible between the top and bottom slots. 

 

Take off the blanking plate by removing the fixing screw. 

 

Keep the blanking plate and screw in a safe place. You 

 

will need it, if you remove a module, to close the chassis 

 

to the ingress of dust and maintain the correct cooling 

 

airflow. 

 

Slide the remote end of module into the runners and 

 

push home firmly to connect to the backplane.

 

Secure the module with the screws provided. 

 

Details of the permissible combinations of modules and  

 

3Com products are given later in this user guide.

 

Connecting Cables

 

Connect the module output socket to the input of the unit 

 

to which you wish to provide an alternative power source 

 

using one of the special cables.  Use a standard cable 

 

(supplied with this module) to provide managed 

 

redundancy or a special ‘Y’ cable (available from your 

 

supplier) where full redundancy (resilience) is required. 

 

Details of how to use the ‘Y’ cables are given on the guide 

 

which accompanies the cables.

 

After installing the module, this guide should be stored 

 

with your other 3Com user guides.

 

If the product you are connecting to the Power 

 

Module does not have the auto-enable feature 

 

(see 

 

SuperStack II Advanced RPS User Guide

 

,

 

 

 

part number DUA1607-0AAA0X), ensure the 

 

mains cable is removed from it before 

 

attempting to connect it to the Advanced RPS.

!

!

!

Reviews: