Introduction 

 
This quick start guide introduces the basic controls and functionality provided with the WorkSeries controller. This 
reference guide is meant only as a secondary reference. This guide should be used in conjunction with the 3D Platform 
WorkSeries User Manual, which can be downloaded from our website at www.3dplatform.com. 
 

G-Code Console Operation 

 

From the Touch Screen 

 
1.

 

Select 

the “

Console

” 

tab at the bottom of the touch screen. 

2.

 

Select the keyboard symbol at the top of the touch screen. 

 

3.

 

Type in the g-code or m-code you wish to execute. 

4.

 

Press the enter key on the touch screen keyboard. 

 

5.

 

Read the feedback message corresponding to the command executed (if applicable). 

6.

 

Verify the result corresponds to the expected result of the command sent. 

 

From the Web Interface 

 
1.

 

Locate the “

G-Code Console

” at the left side of the web interface.

 

2.

 

Type the command to be executed into the command line and press enter. 

3.

 

Read the feedback message corresponding to the command executed (if applicable). 

4.

 

Verify the result corresponds to the expected result of the command sent. 

Note: 

For a list of g-codes and m-codes supported by our controller refer to our support page at support.3dplatform.com. 

 

Wi-Fi Setup 

 

Wi-Fi Connection Setup

 

 
1.

 

With the control box turned on, select 

the “Console” 

tab on the touch screen. 

2.

 

Select the keyboard symbol at the top of the touch screen. 

 

3.

 

Type 

M552 S0

 

into the keyboard to turn off Wi-Fi connection.  

4.

 

Press the Enter symbol to run the command (Repeat this step for following commands). 

 

5.

 

Type 

M552 S1

 

into the keyboard to turn on Wi-Fi connection. 

6.

 

On your computer or mobile device, open the Wi-Fi (network) connections list. 

7.

 

Select “Duet Wi

-

Fi” and connect.

 

Note:

 If network does not appear, enter M552 S2 in Console on touch screen.

 

8.

 

Open a web browser and type the IP address 0.0.0.0 into the browser bar. 

Note: 

If 0.0.0.0 does not work, try 192.168.1.1 

9.

 

In the menu, select your local Wi-Fi network and enter the network password. 

10.

 

You should receive an “All Done!” message. 

 

11.

 

Disconnect your PC or mobile device 

from the “Duet Wi

-

Fi” network

12.

 

Power cycle the controller to complete the setup (Black Button, followed by Green Button). 

 

 

Summary of Contents for WorkSeries 200 Series

Page 1: ...J 3D PLATFORM WORKSERIES QUICK REFERENCE GUIDE 200 300 400 Series VERSION NOVEMBER 2017 6402 East Rockton Road Roscoe Illinois 61073 USA...

Page 2: ...6 Bed Compensation Mesh Bed Leveling 6 Macros 7 Need Help Have questions or need help with your WorkSeries 3D printer Please submit a ticket at our support page and our support team will be happy to h...

Page 3: ...enter 3 Read the feedback message corresponding to the command executed if applicable 4 Verify the result corresponds to the expected result of the command sent Note For a list of g codes and m codes...

Page 4: ...1 Locate the home symbol on the touch screen for the axis you wish to home and press one time Symbol Function Home all axes Home X axis only Home Y axis only Home Z axis only Note Can only be perform...

Page 5: ...rease the temperature as necessary 3 Push the set button 4 Then click on the EXT1 symbol Pushing the EXT1 symbol multiple times will cycle through the Active Standby states Red is Active Yellow is Sta...

Page 6: ...lect the amount you wish to extrude or retract 3 Select the speed you wish to extrude or retract 4 Press the extrude or retract button Note When retracting filament completely out of the hot end it is...

Page 7: ...speed to speed up or slow down the print as necessary 3 Adjusting Acceleration a Select Macros menu on the touch screen b Select the predefined high medium or low acceleration macro c Verify the accel...

Page 8: ...rrors macro 3 Verify the bed probe has a solid red light Note If there is no light verify that the probe is not extended by selecting the Retract Probe macro from the Macros menu If the probe still ha...

Page 9: ...nu on the bottom of the touch screen 2 Select the macro that you wish to run 3 Verify that the machine responded to the macro properly From the Web Interface 1 Navigate to the Macros menu on the left...

Reviews: