3D Systems, Inc.
102
p/n: 15-D100, rev. D
2. Use a 5 mm Allen wrench to attach the grounding wire to
the filter.
3. Roll the new filter behind the DMP system.
4. Remove the seals from the filter inlet and filter outlet ports.
5. Remove the KF50 clamp from the filter outlet port.
6. Remove the cover lid and store the cover lid for later use.
7. Remove the centering ring. The centering ring may stick
slightly to the filter housing. If needed, pry it loose with a
plastic tool (such as a scraper).
Caution: The filter is charged with argon gas. It is
normal for some of the argon gas to be expelled
from the filter when the centering ring is
removed.