13. Remove the KF50 clamp from the inlet port of the process
filter.
14. Repeat steps 6 through 13 for the filter inlet port and the
filter inlet valve assembly.
15. Once both valve assemblies are mounted on the process
filter, the filter can be transported from its secure location
to its position behind the DMP system.
16. Once in position, connect the oxygen sensor on the outlet
valve and tighten the philips screw.
17. Next, install the inductive valve sensors
PNV2
&
PNV3
.
a. Uncheck
ValvesFilter
to close valves 2 and 3.
b. As show in the adjacent figure, slide the inductive
sensor all the way forward into the slot.
c. Next, slide the sensor back gently until the orange light
goes on.
d. Use a small flathead screwdriver to secure the sensor
in position.
18. Connect the compressed air tubes labeled PNV2 & PNV3 to
the push-fit connections on the corresponding valve.
19. On the rear control panel, turn the main compressed air
valve clockwise to open the compressed air supply.