3D Systems, Inc.
113
p/n: 15-D100, rev. D
7.6 DMP DEPOSITION
7.6.1 Fix ‘Unsafe filter pressure’ message
An automatic solution is available in DMP Deposition software from version v21.0.0 onwards.
7.6.2 Detecting of job processing capability failed after restarting DMP Deposition
Available in DMP Deposition software from version v21.0.20 onwards.
When the DMP Deposition program starts, it verifies if the right machine conditions are met to allow for a job start. If the
machine conditions are met, the ‘Run job’ button can be pressed.
If this detection failed during program start, go to menu Controllers > Verify if ready for processing. This will repeat the
evaluation. After successful verification, you can press the ‘Run job’ button again.