3D Systems, Inc.
23
p/n: 15-D100, rev. D
1
2
3
4
5
7
6
3.3 DMP Flex 350
Process chamber door
: creates a gas tight seal with the process chamber and protects the operator from the laser.
Glove ports
: these allow the user to access the build module while the door remains closed.
Process chamber window
: allows the operator to look inside the process chamber but remain protected from laser
radiation.
Stack light
: the stack light consists of four lights that indicate the state of the machine.
• Red - Vital machine error
• Orange - Error but machine is still operational
• Green - Machine is fully operational
• White - Laser is ready
Control panel
: the control panel holds all buttons used to start up the machine.
1
2
3
4
5
• Emergency off: puts the machine in a safe state, activating the safety circuit
• Key switch: switches between operator and service mode.
• On: starts up the machine after turning on the main power switch and 24 V DC.
• Hold to run: button that needs to be held in order to activate certain components.
• USB 1 & 2: USB connections for external devices.
Main power switch
: The main power switch is used to switch the main 400V power
supply to the printer on and off.
Operator PC:
the DMP Flex 350 printer module is controlled by this computer.
6
7