3D Systems, Inc.
29
p/n: 15-D100, rev. D
30
31
RPM cart
: this cart is reserved to remove the DMP
Flex 350 RPM (removable printer module) out of the
printer or store a DMP Flex 350 print module, in case of
multiple print modules. This module cannot be used to
transport any other types of loads.
30
Chiller
: the chiller is connected to the DMP Flex 350
system with flexible hoses and circulates and cools
cooling liquid used to keep the laser components at a
set temperature. It requires a mixture of tap water and
a cooling fluid additive. The tap water must comply with
the water quality standard mentioned in the table in
§3.7 Chiller
of the
DMP Flex 350 Facility Guide (p/n:
15-D99)
.
Cooling fluid additives recommended by SMC are:
Hexid A4, Controlxid1642, CCl105, Cool flow IGE,
Dowcal 100 and opti. The correct mixture of tap
water and cooling fluid additives must be according to
SMC guidelines.
Caution: These cooling fluid additives need to be
supplied by the customer.
31