3D Systems, Inc.
54
p/n: 15-D100, rev. D
Take into account that:
• A process filter name must be unique across the site. Thus, each individual filter element must have a different
name, independently of what printer it is connected.
• It is strongly recommended to clearly write the filter name with a permanent marker on the filter.
• The process filter manufacturer serial number can be used (can be found on the small QC sticker) or customers
can define their own numbering, and even bar code stickers that can be scanned with barcode scanner, instead
of entering the code by hand.
Select
Process filter
>
Show printer details
to get more
information about the process filter that is currently
connected to the system.
Select
Process filter
>
Disconnect filter…
when a process
filter is full or when you want to (temporarily) disconnect
the filter before performing a material change on the
printer.
The details of the filter will be saved in the database on
the DMP Server. The available used filters can always
be listed again (see the
Connect
dialog), and can also
be reconnected. The filter details are stored, so that no
information is lost.
Caution: It is stronly recommended to write down
the unique identifier on the process filter itself!
The software will verify the filter pressure to ensure it is
safe to disconnect the filter. If the pressure is not safe,
then the filter preparation cycle will have to be run first.
Click the red warning text to get more information in
that case.
After successful disconnect in the software, you can
proceed with physically disconnecting the process filter
(for more information, see chapter User Maintenance).