p/n: 15-D100, rev. D
3. When the measurements are completed, click
Apply new
calibration factors
to
temporarily
apply the calibration
factors.
The example to the right shows the completed
measurements for a 400 W laser.
5. Click
Save to machine configuration
. The content of the
measurement logging window can be saved by clicking the
Save
icon in the bottom right corner and then specifiying a
location for the log (text) file.
6. Close the
Laser power calibration
window when the
message
You can now close the window
appears in the
message board.
4. As a double check, click
Perform verification
measurements
. Verification will take +/- 5 min.