Locate the 3D printer system in a convenient location meeting the requirements specified in this document. To ensure optimum
performance, it is important that the printer be installed in a clean, dry, air-conditioned room . Avoid placing the printer in any
environment with airborne contaminants, including cigarette smoke, fumes, and mechanical particulates that can adversely
affect the long term performance of the equipment .
The atmosphere in the ProX SLS 6100 installation room must meet the following specifications:
ATMOSPHERIC VARIABLES
REQUIREMENTS
Room temperature controls
Heating and air conditioning installed
A/C not blowing on top of process station
Temperature
Operating range: (16-32) °C; (60 to 90) °F
Stability: ± 2 °C (± 5 °F)
Non-condensing relative humidity No higher than 70%
Room air changes
4 per hour minimum
Heat dissipation
Maximum: 5kW (17,000 BTU/hr)
Average: 2 .4kW (13,000 BTU/hr)
Atmospheric corrosives
None; Clean Dry Air (CDA) is required
ProX SLS Noise output
The A-weighted sound pressure levels measured at 1 meter from the surface of the
machinery and at a height of 1 meter from the floor is as follows:
•
Ambient 62 .9dB
•
Front 68 .3dB
•
Left 72 .0dB
•
Right 72 .6dB
•
Rear 70 .0dB
NOTE: ATEX-MQC must be installed in a room that meets the same or higher ATEX-level certification.