3D Systems, Inc.
35
p/n 76-D020 Rev. A
2 .
The laser window is enclosed in the baffle assembly. Remove the top cover of the as
-
sembly using a 2 .5mm allen wrench . Be sure to loosen the screws in a cross-pattern
so that the tension is relieved evenly .
3 . Set the screws and the lid to the side .
O-Ring
Side of lens
that needs to
be cleaned
Remove lid and set to the side
Cover with lens tissue
Remove and clean O-Ring
Replace into baffle assembly
Turn the assembly over
Remove lens and set on work table
4 . Cover the lens with a lens tissue and turn the assembly over so that the lens comes out .
5 . Set the lens aside on the work table . This will be the side of the O-ring that will need to be cleaned the most . However, both
sides will be cleaned in this procedure .
6 . Remove the O-ring and wipe it clean .