DIY/Miscellaneous Vent Adapters 

3DUPfitters has a wide variety of vents designed to meet your custom venting needs.  They 

are 

designed to work with standard 3” or 4” clothes dryer hose available in any hardware store.  

Adjust the hose clamp to be right next to the ridge for the best fit.

The adapters are intended to be flexible so you can design a configuration that’s best for your 
situation. Here’s an example setup with the CR-10/Taz6/Ender 5 Plus vent kit.  For this you'd 
need to order a hose, clamps, and dryer window vent from your hardware store.

The Prusa/Ender setup is a bit more complicated since window inserts are all 4", while the 
hose we recommend is 3".  This setup adds an 3"->4" hose adapter, and the 3" hose is small 
and doesn't overwhelm the small enclosure. Note that with this setup you need 2 3" clamps 
and 1 4" clamp.  

Copyright 2022 3D Upfitters LLC

9

Summary of Contents for Carbon Air Filter

Page 1: ...Air Filter Vents Installation Manual 4 0 July 2022 Copyright 2022 3D Up fi tters LLC 1 ...

Page 2: ...This page intentionally left blank Copyright 2022 3D Up fi tters LLC 2 ...

Page 3: ...w If you re already got an enclosure or are creating one for yourself you ll need to cut a hole for air fl ow and four holes to mount the fi lter and fan The hole should be 78mm in diameter and the holes are 70mm apart in a square pattern There is a DXF fi le you can download from the product page on the website if you want to laser or CNC your Copyright 2022 3D Up fi tters LLC 3 ...

Page 4: ...u ll want to connect the fan to the fi lter so that the air is pulled out of the enclosure and through the fi lter Attach the Filter to the Panel There are two sizes of holes with 3DUP fi tters enclosures for 60mm and 80mm fans With the larger 80mm sized holes the screws are inserted from inside the enclosure and through the nuts slotted into the fi lter itself as shown below The fi lter is mounte...

Page 5: ... fi lter on the outside of the enclosure Insert the screws only part way into the fi lter to make sure the screw ends have caught into the nuts before starting to tighten Smaller enclosures such as the Prusa have 60mm holes and thus need an adapter To prepare the 80mm to 60mm adapter insert an M4 square nut in each corner as shown below Copyright 2022 3D Up fi tters LLC 5 ...

Page 6: ...s You can use a needle nose pliers or even a pen tip to adjust the location The adapter is then connected to the fan fi lter combination using 40mm M4 screws Insert all 4 screws only a small way in before attempting to tighten Copyright 2022 3D Up fi tters LLC 6 Aligned Correctly Aligned Correctly O ff Center O ff Center ...

Page 7: ...The holes on the 60mm side will now align with the 60mm holes on your Prusa Ender 3 or other small enclosure and the fi lter can be attached with 12mm M4 screws Copyright 2022 3D Up fi tters LLC 7 ...

Page 8: ...our vents paired with a standard dryer hose They can also hook to any DIY enclosure by simply creating the right size hole Inline Fan Our latest venting kit features an inline fan that is both very powerful and adjustable The general layout is shown below Ideally you ll want to place the inline fan as close as possible to where it exits your workspace The idea is to keep as much as possible of the...

Page 9: ... you can design a con fi guration that s best for your situation Here s an example setup with the CR 10 Taz6 Ender 5 Plus vent kit For this you d need to order a hose clamps and dryer window vent from your hardware store The Prusa Ender setup is a bit more complicated since window inserts are all 4 while the hose we recommend is 3 This setup adds an 3 4 hose adapter and the 3 hose is small and doe...

Page 10: ...with parts that aren t included in the kits you can fi nd fl exible 4 dryer duct hoses or fl exible 3 hoses online or at most hardware stores This can be connected to the outside using the same techniques you d use for a clothes dryer or you can purchase one of the many compatible window venting kits These items are not included and Copyright 2022 3D Up fi tters LLC 10 ...

Page 11: ... stock them since they re readily available at local hardware stores The fan can either be plugged into a USB power supply not included or the wires stripped and connected directly into some models of 3D printer Copyright 2022 3D Up fi tters LLC 11 ...

Page 12: ... powerful enough to blow open most fl aps and ducts The window venting kid mentioned in the previous paragraph either needs to have the fl ap taped up or removed Air Vent with default Flag Air Flag Taped Out of the Way Copyright 2022 3D Up fi tters LLC 12 ...

Reviews: