3DGence INDUSTRY F340 | 33
version 1.0/07.2017
Z Measure
– the option used to test and set a correct Z Offset value. Once the Z Measure key is pressed, the printer
detects the T0 head position by using load cells. Then, in the same place it takes the same measurement for T1 position.
The difference resulting from the measurement is saved in the Z Offset box. To confirm the measurement, press the Save.
Reset
– restores the default deviation values.
Save
– saves the introduced changes to printer memory.
Autocompensation Settings
– menu referring to printer autocompensation settings:
Z Offset
– manual correction of the distance in Z axis. It allows for adding (or subtracting) a specified value to the measure
-
ment point in Z axis (autocompensation). In practice, if Z offset is set to 0.1 mm, the print will be started higher by this value:
Height of the first layer: 0.2 mm
0.2 mm + Z Offset: 0.1 mm = actual start height: 0.3 mm
The option can be useful when using adhesion bands or pads.
When using such a solution, Z-offset should be set to a value corresponding to the pad thickness. The parameter can
adopt negative values, then the print start point will be set lower (closer to the table).
CAUTION:
negative Z offset values can never exceed the first layer thickness!
Pressure
– sensitivity of the measurement point for the Z axis autocompensation. It allows for defining the value of head
pressure during height measurement. Sensitivity can be adjusted within the range from 20 (approx. 0.5 g) to 120 (approx.
4 g). In the case of easily flowing materials it may be necessary to increase the measured pressure to reduce the risk of
head homing on the material outflowing during material measurement. Otherwise, the print may start too high because
of taking into account the thickness of the material that has flown under the head.
X Position
– defines the distance between the autocompensation measure point and the homing base in X axis. By mod
-
ifying this value it is possible to move the measure point in X axis.
Y Position
– defines the distance between the autocompensation measure point and the homing base in axis Y. By mod
-
ifying this value it is possible to move the measuring point along Y axis.
RESET
– restores default values for this menu.
SAVE
– saves all introduced changes to device memory.