11
7.0 Bonding for Shielded Cable
Note:
Use caution when installing shield bond connector so underlying layers of cable are not damaged.
7.01 When splicing any standard, terneplate type, shielded fiber optic cable, install the 4460-D Shield Bond
Connector.
7.02 Prepare cable/tab 180 degrees from shield bond connector location and insert base.
Note:
When a non-core wrap fiber optic cable is being used, use caution to not damage buffer tubes
when inserting connector base.
7.03 Install the connector top over the stud and tighten firmly with one
of the securing nuts. Place the braid over the connector stud and
secure in place with the nut.
7.04 If double sheath, double shield fiber optic cable is being used,
both outer shield and inner shield need to be bonded.
Leave 3/4" inner sheath and 3/4" of core wrap exposed and install
two shield bond connectors 180 degrees apart per practice. Both
shield bond connectors need to be commoned with a bond strap.
7.05 When bonding LXE cable, the two LXE members must be placed in the two slots at the back of base unit
after it is installed. Twist LXE members together twice.