17
9.03 Press cable seals onto cable entrance port(s).
9.04 Attach each cable to splice case by installing and tightening hose
clamps over previously wrapped DR Tape on the down brackets.
Double sheath cable will have hose clamp tightened over metallic
tape previously placed on the cable instead of DR Tape.
9.05 Place cable ties outside of splice case. Install one large green
cable tie on the "C.O. Cable" and trim. Install one large blue
cable tie on the "Field Cable" and trim.
10.02 Place ground stud protector cap on ground studs.
10.03 If separate external grounding is not required, bond across splice
to either ground stud.
10.0 Grounding for Shielded Cable
10.01 Remove ground stud protectors. If bonding to central clamp is
not required, remove strap from external ground stud. If
separate external grounding is required, bond "C.O. Cable" and
"Field Cable" directly to the closest ground stud.