27
b. Lay two strips of sealing cord 1 1/2" (38 mm) in length
between the cable entrance ports on each end of the splice
case base, or one 3" (76 mm) length folded in half to fill the
channel.
15.02 Seal plug construction:
a. Select a plug for each vacant cable entrance port.
b. Wrap each plug with 1 1/2" (38 mm) sealing tape. Sealing
tape O.D. should be flush with plug O.D. Do not overwrap.
c. Press seal plugs into each vacant cable entrance port.
15.03 Set splice case cover directly on top of the splice case base.
15.04 Turn all bolts until they have been threaded several complete
turns into the nut inserts or until the cover rests on top of the
sealing cord.
15.05 Tighten all bolts in numbered sequence. A torque wrench is not needed. If a torque wrench is used, do not
exceed 20 Ft. Lbs. (240 in Lbs.).
Note:
Do not use an air drive wrench.
9
6
2
8
4
7
5
1
3
10
15.06 After five minutes, retighten all bolts on the splice case.
15.07 Flash test splice case with 10 psi maximum.