31
20.0 Splice Case Assembly with One Adapter
20.01 Seal splice case walls:
a. Lay sealing cord into channel along both sides of the splice
case base. Do not stretch sealing cord.
b. Lay two strips of sealing cord 1 1/2" (38 mm) in length
between the cable entrance ports on each end of the splice
case base, or one 3" (76 mm) length folded in half to fill the
channel.
c. Press seal plugs into each vacant cable entrance port.
20.03 Set butt adapter 1 (flange side down) as is on top of splice case
base.
Note:
These steps are done to seat cord between splice case and
butt adapter.
20.04 Set cover directly over butt adapter 1.
20.02 Seal plug construction:
a. Select a plug for each vacant cable entrance port.
b. Wrap each plug three times with 1 1/2" (38 mm) sealing tape. Sealing tape OD should be flush with plug
OD. Both ends of tape should be feathered to prevent leak paths. Do not overwrap.