20.05 Tighten all bolts in numbered sequence. A torque wrench is not
needed. If a torque wrench is used, do not exceed 20 Ft. Lbs.
(240 in Lbs.).
Note:
Do not use an air drive wrench.
10
3
1
5
7
8
4
2
6
9
20.06 Follow steps 20.01 through 20.04 to seal butt adapter to cover.
20.07 After five minutes, retighten all bolts on the splice case.
20.08 Flash test splice case with 10 psi maximum.
21.0 Cable Addition Placement, Preparation and Installation (Two Adapters)
21.01 For the double butt adapter splice case, replace all ten 2" (51 mm) bolts inserted in the splice case cover
with the ten 4.95" (126 mm) bolts supplied with the 2181B kit.
21.02 Cables should be placed in cable entrance port in a butt
configuration for easier storage.
21.03 Cable preparation - (See Section 5.0).
21.04 Stack Central Clamps
Note:
Buffer tube retainers may be removed for installation of central clamp and additional trays.
Replace buffer tube retainers after clamp and trays are installed.
a. Remove the splice trays from the central clamp or universal
adapter and set aside. If the universal adapter is used, it must
be removed from the central clamp. Remove the two fillister
head screws holding the central clamp to the splice case
base.
b. Place the third level central clamp directly on top of the
second level central clamps and secure the two fillister head
screws supplied with the 2181B kit.