background image

13

12

3M™ Portable Compressed Air Filter and Regulator 256-02-00, with
Carbon Monoxide Filtration and Monitor

Fig. 4 

Remove any large volumes of oil/water from supplied air line prior to connecting the system.
Purge air through the system for a minimum of five (5) minutes on initial start-up.

NOTE:

If excessive oil/water is present, install a separate coalescing prefilter such as the 

3M™ Coalescing Filter Assembly W-3012 prior to the system inlet.  (Fig. 4)

DO NOT

install model 3M™ Portable Compressed Air Filter and Regulator Panel 

256-02-00, with CO Filtration and Monitor in a compressed air system where the compressed air
has less than 20% R.H.  The fourth stage carbon monoxide filter will not function correctly.

Install the industrial interchange plug into the threaded inlet to the panel.  Install all four (4)
industrial interchange quick disconnects into the four (4) threaded outlets from the panel.

Connect the inlet air supply and outlet compressed air hoses.

Pressurize the system and set the regulator to the appropriate pressure required by the respirator air
control device.

Adjust air sample metering valve’s adjustment knob (Fig. 5) so the black floating ball is within 
the 

green boxed

area etched on valve body.  Proper air sample is now being metered to the CO

monitor.  Periodically check to be sure ball is floating freely in this area by turning adjustment
knob and noting movement of ball.

Fig. 5

To meet NIOSH requirement 42 CFR 84, subpart 84.150 for minimum and maximum airflow
(4-15 cfm, 113-425 lpm), the air control valves approved for use with the 3M respirators must
be operated within the supply pressure ranges and hose lengths stated in their 

User Instructions

.

Failure to do so may adversely affect respirator performance and result in sickness or death

.

W

WARNING

Serious injury could result if the AIR SAMPLE METERING VALVE is not properly adjusted.
Proper sample airflow to CO monitor is required for monitor to give correct CO level readout.

Failure to do so may result in sickness or death.

W

WARNING

34870214383  10/28/08  12:38 PM  Page 15

Summary of Contents for 256-02-00

Page 1: ...r Building 235 2W 70 St Paul MN 55144 1000 3M Occupational Health and Environmental Safety Division 3M Canada Company P O Box 5757 London Ontario N6A 4T1 FOR MORE INFORMATION In United States contact...

Page 2: ...Carbon Monoxide Filtration and Monitor 7 Replacement Parts 8 Accessories 8 Set Up Procedures 8 OPERATING INSTRUCTIONS 10 Carbon Monoxide Monitor 11 3M Portable Compressed Air Filter and Regulator 256...

Page 3: ...he filtered compressed air will meet the requirements of Grade D breathing air In Canada refer to the requirements of CSA standard Z180 1 The line pressure must be kept within safe limits 125 psig 8 7...

Page 4: ...cfm 1416 L min Inlet pressure recommended 90 120 psig 6 2 8 3 bar Outlet pressure range 0 125 psig 0 8 6 bar Operating temperature range 68 150 F 20 65 C compressed air temperature at inlet of panel 0...

Page 5: ...e with the 3M respirators must be operated within the supply pressure ranges and hose lengths stated in their User Instructions Failure to do so may adversely affect respirator performance and result...

Page 6: ...nts The filter and regulator panel comes with a 3M Carbon Monoxide Monitor designed to provide continuous direct read CO monitoring The carbon monoxide monitor in the filter and regulator panel is CSA...

Page 7: ...th and safety standards respirator selection tables contained in such publications as ANSI Z88 2 1992 CSA Standard Z94 4 or pursuant to the recommendations of an industrial hygienist The employer must...

Page 8: ...and outlet compressed air hoses Pressurize the system and set the regulator to the appropriate pressure required by the respirator air control device Adjust air sample metering valve s adjustment knob...

Page 9: ...Refill the third stage aluminum tube by sliding the new third stage filter cartridge into the aluminum tube from the bottom Make sure that the flow direction arrow on the new third stage filter cartr...

Page 10: ...ed in duration to the above one 1 and two 2 year periods respectively 3M shall not be liable for loss of use of any of its products or incidental or consequential costs expenses or damages incurred by...

Reviews: