3
3.7 Slide the connector into the guiding groove against the connector locator stop
⑦
.
3.8 Place the cable
⑩
into the base plate serrations. For end-to-end assemblies, smoothly slide the
cable between cable guides
④
⑥
, under the guiding wing
②
against cable stop
⑨
. For daisy chain
assemblies, until the required length is obtained. The cable will fit between the cover and the
contacts of the connector.
Note: If the cable is not entering into the connector smoothly, check the flatness of the cable used.
3.9 Complete the assembly by closing the press handle.
Note: Never operate a pneumatic press without ensuring that there is a connector in the locator plate.
3.10 Raise the press handle and remove the finished assembly by lifting the guiding wing
②
with the
lever
①
.
3.11 Visually inspect to ensure that: a) The cover is fully locked. If not, check the shut height gauge.
b) The cable is correctly aligned in the cover. If not, check the cable guide adjustment.