Distributor of 3M: Excellent Integrated System Limited
Datasheet of 3443-96 - LOCATOR PLATE PLUG
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com
4
78-9100-5422-6-B
Rotate the shut height to lower or raise
3.5
adjustment feature until the bottom of the shaft
contacts the desired position on the shut height
gauge. (Figure 3 and 4)
- Press 3640
Figure 3
Install the locator plate and the appropriate
3.6
platen on the press. The platen should be
positioned parallel with the connector body
and cover.
- Press 3335
Figure 4
Procedures for Connector/Cable Assembly
4.0
Grasp a plug cover strip between thumb and
4.1
forefinger of both hands, with the liner facing
you. Rotate the outermost cover down against
the adjacent cover on the strip, breaking it
from the liner. Pull laterally away from the
strip. Adhesive should be present on the cover.
(Figure 5)
Figure 5
Firmly press ribbed side of cable into the
4.2
alignment grooves on cover. The adhesive will
help it to stay in place. Visually inspect to
ensure that:
a. Cable is properly aligned to cover grooves.
b. Cable end is flush with the cover for end
terminations or perpendicular to cover for
midspan terminations. (Figure 6)
Figure 6
5 / 7