Distributor of 3M: Excellent Integrated System Limited
Datasheet of 3443-96 - LOCATOR PLATE PLUG
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com
78-9100-5422-6-B
5
Place the cable/cover sub-assembly between the
4.3
guides on the locator plate, cover side sown.
(Figure 7).
Position and orient connector body, contacts
4.4
down, over the cable/cover sub–assembly,
aligning cover with the body slots. (Figure 7).
Figure 7
Lower the PRESS HANDLE firmly to complete
4.5
the Cable/Connector Assembly. (Figure 8)
Raise the press handle and remove completed
4.6
assembly. Visually inspect to ensure that :
a. Cover is fully seated and parallel with the
body.
b. Cable is properly aligned with cover grooves.
c. Cover retaining devices on the body are flush
with the cover end.
Figure 8
Procedures for Accessory Assembly
5.0
Optional accessories available for the 3M
™
Locator Plate 3443-96 include: Strain Relief, Pull Tab and Polarizing Key.
Strain Relief:
5.1
a. Bend cable back over the cover.
b. Engage one end of the strain relief onto the
cover retaining device.
c. Snap the other end of the strain relief into
posistion. (Figure 9)
Figure 9
Pull Tab
5.2
a. Slide the pull tab between the strain relief and
the cable. Seal both ends together. (Figure 10)
Figure 10
6 / 7