background image

FILTER REPLACEMENT INSTRUCTIONS       

1.  Place towel under filter to collect any residual water during replacement filter change-out.

2.  Grasp filter and turn to the left (counterclockwise) until filter comes to a complete stop (water automatically turns off).  

Water may leak momentarily from vent tube. This is normal. Gently pull filter downward to remove.

3.  Remove sanitary protective cap from new replacement filter.

4.  Ensure both o-rings are present on the replacement fi lter and are seated into grooves; moisten o-rings with water.  

DO NOT use any petroleum products to lubricate the o-rings.

5.  Insert replacement filter into filter head assembly.  Turn replacement filter one quarter turn to the right (clockwise) 

until it stops.  When fully engaged, the top surface of the filter will be flush with the bottom of the filter head assembly.      
(See Figure 5)

6.  Open faucet and run water for a minimum of 4 gallons (approximately 2 minutes). While system is flushing, check for 

leaks.  Repair any leaks as needed before continuing.  

 

Close filter system faucet.  System is now under pressure and can be inspected for leaks. Repair any leaks as needed 
before continuing. The system is now ready for use. 

CAUTION

To reduce the risk associated with property damage due to water leakage:
 • 

The disposable replacement fi lter 

must

 be replaced every twelve (12) months, at the rated capacity or sooner 

if a noticeable reduction in fl ow rate occurs.

Collet

Backstop

“Using Push-In Fittings”

To Attach Tubing

(1) Push tubing in as far as it will go. 

(2) Tubing must be inserted past o-ring and hit 

backstop. 
Pull tube to ensure it is secured.

To Release Tubing

(1) Push in collet to release tubing. 
(2) With collet held, pull tubing straight out.

To reduce the risk associated with property damage due to water leakage:
  •  Ensure all tubing and fi ttings are secure and free of leaks.

CAUTION

Figure 5

INLET

Push In

Push In

OUTLET

moisten o-rings with water.  DO NOT use any petroleum 
products to lubricate the o-rings.

10. Align lugs of filter with head assembly and insert filter into 

head assembly.  Turn filter to the right (clockwise) until it stops 
(about 1/4 turn).  The filter is now installed.  (See Figure 5)

11.Turn on cold water supply valve and open faucet  to flush air 

from the system.  Run water for a minimum of 4 gallons (ap-
proximately 2 minutes) to flush system.

  Close the faucet.  The system is now ready for use.  System 

is now under pressure and can be inspected for leaks.  Repair 
any leaks as needed before continuing.

6

INSTR8029 0512.indd   4

6/13/2012   9:18:10 AM

Reviews: