SAFETY INFORMATION

Read, understand and follow all safety information contained in these instructions prior to installation and use of 

the 3MRO401 Reverse Osmosis Drinking Water Filtration System. Retain these instructions for future reference.
Intended use:

The 3M

 Reverse Osmosis Drinking Water System (Model 3MRO401) is intended for use in filtering potable water and 

has not been evaluated for other uses.  The product is installed at the point of use and must be installed as specified in 

the installation instruction by a qualified professional.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING

CAUTION

NOTICE

Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious 

injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate 

injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

2

WARNING

To reduce the risk associated with choking:

  • 

Do not

 allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

  • 

Do not

 use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before 

or after the system.  Systems certified for cyst reduction may be used on disinfected water that may contain filter-

able cysts. EPA Establishment #070595-CT-001

To reduce the risk associated with a hazardous voltage due to an installer drilling through existing electric wiring 

or water pipes in the area of installation:

  • 

Do not

 install near electric wiring or piping which may be in path of a drilling tool when selecting the position to 

mount the filter bracket.

To reduce the risk of physical injury:

  • De-pressurize system as shown in manual prior to cartridge removal.

To reduce the risk associated with a hazardous voltage:

  • If the home electrical system requires use of the cold water system as an electrical safety ground, a jumper must 

be used to ensure a sufficient ground connection across the filter installation piping — refer installation to quali-

fied personnel.

  • 

Do not

 use the Filter if the power cord is damaged — contact qualified service personnel for repair.

To reduce the risk associated with back strain:

  • Follow safe lifting procedures.

Summary of Contents for 3MRO401

Page 1: ...dration Hot and cold beverages Cooking and food preparation Pet hydration Aquatic aquariums Optimized For Reduction Of Select Volatile Organic Compounds VOCs System tested and certified by NSF Interna...

Page 2: ...to small parts during the installation of this product To reduce the risk associated with ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without...

Page 3: ...system Where a booster pump is installed on a water system you must install an appropriate pressure relief valve Pres sure relief valve must be maintained and inspected every 6 months Contact a plumbi...

Page 4: ...ing location 5 D Make the faucet mounting hole 5 E Mount the faucet 6 F Prepare the system for installation 6 G Install the feed water connection and tubing 7 H Prefill and sanitize the storage tank 7...

Page 5: ...nothing will interfere with mounting the faucet such as reinforcing ribs support brackets or the cabinet construction If drilling a hole in your sink is required the professional installer should foll...

Page 6: ...Gap is provided by hole 1 above faucet base 1 Familiarize yourself with all of the components shown in the air gap faucet diagram See Fig 2 2 Slide the chrome base plate and rubber washer up the thre...

Page 7: ...y and the tank valve Disconnect the orange and yellow tube from the union connector setting the tank aside while proceeding with the rest of the installation the sanitizing solution should be kept in...

Page 8: ...ween the sink basins for ease of access if space permits K MAKE THE TUBING CONNECTIONS With all of the components in place the tubing connections can be made When routing the tubing between the compon...

Page 9: ...The drain line has a loop in it Air is locked in the air gap outlet There is excessive RO reject flow Solutions Check to see that the drain line is clear of any obstruction and remove the drain saddle...

Page 10: ...ed valve Wait five 5 minutes for the filtration assembly to completely depressurize 2 Remove cover 3 Twist the existing filter 1 4 turn to the left so that the ears on the filter are able to disengage...

Page 11: ...ly and are not designed to sanitize systems that have become highly contaminated from misuse When to Sanitize the Storage Tank Upon start up as described in the beginning of this manual After any serv...

Page 12: ...tion Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclu...

Reviews: