background image

Drilling hole through Porcelain/Enamel/Ceramic Sinks

If you are reading this section, professional installation is highly 

recommended.

Recommended Tools:

•  Variable Speed Drill
•  Porcelain Cutter Tool Set (7/8” Size)
•  Plumber’s Putty

Note:

 It is important to understand this procedure.

1.  The glassy layer of porcelain/enamel/ceramic must be scored 

through to the metal base, creating a disk.

2.  This disk must be removed while protecting the surrounding deco-

rative coating against chipping or fracturing.

3.  The base metal must be drilled through to complete the hole.

Procedure:

1.  Mark center for 7/8” hole.
2.  Form a dam of shallow putty around hole location and fill with 

enough water to lubricate carbide drill bit.

3.  Carefully drill pilot hole through porcelain/enamel/ceramic and base 

metal using a carbide pilot drill bit.  Always operate drill with light 

pressure at slow speed (300 - 400 rpm).

4.  Drill porcelain/enamel/ceramic using special 7/8” cutting tool, 

making certain a complete ring has been cut through to the sink’s 

metal base.

5.  Change to metal cutting drill bit and drill out the center of the ring, 

making sure not to contact other rim of decorative coating.  Cut 

through metal sink base.

E.   MOUNT THE FAUCET

 

Undercounter installations require a faucet with a built-in air gap 

such as the one included with the system.  

Undercounter Installation With An Air Gap Faucet (Air Gap is provided 

by hole 1” above faucet base):
1) 

Familiarize yourself with all of the components shown in the air gap 

faucet diagram. (See Fig. 2)

2) 

Slide the chrome base plate and rubber washer up the threaded 

base of faucet.

3)

  Connect the 1/4” green tubing supplied in the installation kit to the 

smaller barb on the air gap faucet. Push it on firmly until it seats.

4)

  From above the sink counter-top, feed the air gap tubing and the 

threaded nipple through the faucet washer, escutcheon plate and 

bottom washer into the faucet mounting hole and position the 

faucet spout over the sink.

5)

  From below the sink/countertop, install the slotted washer, plastic 

spacer, base nut and hex nut onto the threaded nipple and tighten 

it by hand.

6)

  After rechecking the faucet orientation, tighten the base nut until the 

faucet feels secure, then tighten the hex nut.

F.  PREPARE THE SYSTEM FOR INSTALLATION

 

Check to see that the air charge in the empty tank is approximately 

7 psi (48 kPa). 

Note: 

Check the storage tank air pre-charge. Adjust it if 

necessary.  To help keep the membrane as clean as possible, the RO 

membrane cartridge has been shipped separately in a sealed plastic bag.  

6

Fig. 2

Faucet with Air Gap

Side View

Back View

Air Gap hole

1/4” Standard  

green tubing

Special red “SFC” 

tube from RO

Black 3/8” Reject  

tubing to drain

Blue 3/8” Product  

water tubing connection

Blue 3/8” Product  

water tubing

Faucet washer

Countertop

Bottom washer

Escutcheon plate

Mounting spacer

Threaded nipple

Hex nut

Slotted washer

Base nut

Mounting spacer

1/4” x 3/8” Tube Connector

1/4” x 3/8” Tube Connector

Summary of Contents for 3MRO401

Page 1: ...dration Hot and cold beverages Cooking and food preparation Pet hydration Aquatic aquariums Optimized For Reduction Of Select Volatile Organic Compounds VOCs System tested and certified by NSF Interna...

Page 2: ...to small parts during the installation of this product To reduce the risk associated with ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without...

Page 3: ...system Where a booster pump is installed on a water system you must install an appropriate pressure relief valve Pres sure relief valve must be maintained and inspected every 6 months Contact a plumbi...

Page 4: ...ing location 5 D Make the faucet mounting hole 5 E Mount the faucet 6 F Prepare the system for installation 6 G Install the feed water connection and tubing 7 H Prefill and sanitize the storage tank 7...

Page 5: ...nothing will interfere with mounting the faucet such as reinforcing ribs support brackets or the cabinet construction If drilling a hole in your sink is required the professional installer should foll...

Page 6: ...Gap is provided by hole 1 above faucet base 1 Familiarize yourself with all of the components shown in the air gap faucet diagram See Fig 2 2 Slide the chrome base plate and rubber washer up the thre...

Page 7: ...y and the tank valve Disconnect the orange and yellow tube from the union connector setting the tank aside while proceeding with the rest of the installation the sanitizing solution should be kept in...

Page 8: ...ween the sink basins for ease of access if space permits K MAKE THE TUBING CONNECTIONS With all of the components in place the tubing connections can be made When routing the tubing between the compon...

Page 9: ...The drain line has a loop in it Air is locked in the air gap outlet There is excessive RO reject flow Solutions Check to see that the drain line is clear of any obstruction and remove the drain saddle...

Page 10: ...ed valve Wait five 5 minutes for the filtration assembly to completely depressurize 2 Remove cover 3 Twist the existing filter 1 4 turn to the left so that the ears on the filter are able to disengage...

Page 11: ...ly and are not designed to sanitize systems that have become highly contaminated from misuse When to Sanitize the Storage Tank Upon start up as described in the beginning of this manual After any serv...

Page 12: ...tion Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclu...