Splicing the frames on the second side of a double-sided cabinet.
a) After the first side of the cabinet is completely spliced, install one frame in the other side of the
cabinet. Rest the frame on the pivots and attach the safety cable to the frame.
b) Mount the splice head alongside the frame. Splice the field conductors and block tails with the same
method as the other frame splices.
c) Complete the splices, and bundle and store them following your company procedures.
d) Repeat this procedure with the middle frame.
e) Support the frame close to the last frame position. Do not install it into the cabinet. Keep it off the
ground to prevent damage.
f)
Untie the block tails from the the frame. Lay it on the metal side. Bring the tails to the cabinet.
g) Mount the splice head in the cabinet so the splices can be bundled and stored in the same method as
the frames.
h) Splice the field conductors and block tails following your company practice.
i)
Complete the splicing and install the frame. Attach the safety cable to the frame.
j)
Bundle the splices in the frame the same as the other frames.
k) Secure all frames in the upright position.
10.0 Identification of 3M
™
Self-Strip Blocks 4320 Using Number Labels
10.1
Remove protector tape from identification pads on
the blocks in the cabinet.
10.2
Select labels, blue for distribution or green for
feeder. Detach a strip of 20 labels with your count
from sheet. Carefully remove protective backing
from strip.
Note: 3M
™
Tag Labels 4379 PYL Purple and Yellow tag
labels available for DSL and VDSL marking in
counts 1-1800, 1801-3600 and 3601-5400.
10.3
Align the proper number such as 1-6-11, etc. with
the block pads on left and press into place. Align
numbers such as 5-10-15, etc. with right side block
pads and press in place. Remove the top liner of
the numbers.
10.4
Fill in Binding Post Log on the cabinet door with
the cable pair count information.
Summary of Contents for 4220-ET