78-0013-6691-9-A 5
5.0 Splicing
5.1 Splice the feeder cable group(s) to the appropriate 3M
™
Terminal Block Tail(s) per your company’s practice.
5.2 Bundle completed 3M
™
Splice Module(s) and secure them with 3M
™
Cable Ties within the splice chamber.
5.3 Close the splice chamber cover and secure the lock plate bolt.
6.0 Running Jumpers—3M
™
Quick Connect System (QCS) 2811 Block
6.1 Open the feeder pair jumper cap by pushing up on the
latch and rotating up. Insert jumper wire ends A (tip)
left and B (ring) right into wire openings in the cap,
making sure they are inserted all the way to the back
of the cap.
6.2 While holding the jumper wires in place, close the cap
and press to snap the latch firmly into place.
6.3 Route the jumper wires to the distribution pair
through wire loops on the block ends and through
vertical and horizontal wireways. Cut jumper wires
to appropriate length, leaving at least 2" (51 mm) of
slack.
6.4 Terminate the jumper wires to the distribution pair by
repeating the procedure described in steps 6.1 and 6.2.
6.5 Terminate additional jumper wires by repeating the
above procedure.
6.6 To remove jumper wires, open the cap and pull the
wires straight out from block.
6.7 Route the wire below the connected cap.