78-0013-6691-9-A 7
10.0 3M
™
Priority Caps
10.1 Priority caps are used to designate special purpose
circuits and prevent entry of the 3M
™
Single Pair Test
Probe.
10.2 To install priority caps, place over the jumper cap of the
pair to be marked and push it into place. Latching is
indicated by an audible snap.
11.0 Multiple 3M
™
Indoor Building Entrance Terminal (IBET) 4588VTP, 4588VSTP,
4588VTPC and 4588VSTPC Installation
Note: Use this application when the required cable
pair capacity exceeds the capacity of a single
IBET.
11.1 The design of the splice chamber and the grooved cable
glands make it possible to stack the IBET vertically,
up to three of the same cable pair count and within the
diameter limits in the chart in 3.1.
11.2 Mounting the IBET
a)
Mount the IBET bodies using the cable glands
to position them.
b)
Assemble the feeder cable strain relief
according to Section 3.0 and prepare the feeder
cable so that 21" (533 mm) of free conductor
length will be in the last IBET.
1" (25 mm)
minimum
21"
(533 mm)
2.75" (70 mm)
minimum