10.0 Retrofit on PST Pedestal Splice Closures
10.1
Existing 3M
™
PST Pedestal Splice Closures can be converted
to re-enterable closures by using the following procedures.
Cut PST from top to bottom and pull it away from the closure
body and sealing collar.
10.2
Remove vinyl tape from butt of closure and slide closure off.
9.0 Closure Reentry
9.1
Re-entry of closure is accomplished by pulling out and pushing
down the wire form latch. The latch will lift the dome of the
closure from the base as it is pulled.
Note:
Replace desiccant bag if necessary. Replacement bags
can be obtained from 3M, order #78-8054-9675-5.
9.2
To replace the closure dome, PLACE dome on to the base. Close
the wire form latch, insuring that it catches the protrusions on the
dome.
Note:
Wipe O-Ring clean if dirty and relubricate. Cable grease is
acceptable.