10.3
Remove vinyl tape from foil bag and slide foil bag off splice.
Note:
The foil bag is not required in the reenterable dome
closure.
10.4
After completing repair, take gel sealing strip and remove the
packaging.
Note:
For 4608 and 4608XL use gel sealant strip only.
Wrap the gel sealing strip around the existing mastic end seal.
Place new dome closure on the seal.
10.5
If more than one wrap of gel is visible, trim the strip, and
rewrap. Repeat until only one wrap of gel is visible. A
4600GSS gel sealant strip may be necessary to build the seal
to the proper size.
10.6
Wrap vinyl tape that is less than 1" (25 mm) wide around seal
to hold tail in place, if necessary.
Note:
Do not completely cover the outside surface of the seal
with tape.
Note:
For 4608 and 4608XL, base plate is not required.
10.7
Complete assembly as outlined in the installation procedures.