7
Note:
Place ground wires and drop wires between layers in gel
sealing strip. Ensure wires have one layer of gel between
them and cable sheath. There should be at least 0.25" (6
mm) between wires.
7.3
Install gel end seal core 2" (51 mm) below the sheath opening.
Pull lips of seal, created by cutting and removing plug, around
cables. Remove packaging from gel sealing strip. Wrap the gel
sealing strip around the core and ground wires with a slight
tension.
7.2
Slit gel end seal ports along the length of plugs for desired
number of cables to be installed and remove plugs.
Use plugs 1 and 2 for main cables and plug 3 for branch or
terminal cable.
7.0 4604 and 4606 Closure Installation
7.1
Cut and remove packaging from gel end seal core.
Note:
A fourth plug is available on 4606 closure.