9.0 Closure Installation – 4604GW and 4606GW
9.1
Remove cardboard insert and pull core tail through the center of PST
until core is even with PST edge.
9.2
Slide PST over closure so that PST tail is pointed toward the top of
the closure. The core tail MUST be unwound upward. Position PST
bottom edge between the bottom of the wire form latch and the base's
top rib.
Note:
Optional method is to put closure over the splice bundle and
position PST 2" (51 mm) below the gel end seal. While holding
the PST and closure with one hand, unwind the core by pulling
on the core tail with the other hand in an upward and outward
COUNTERCLOCKWISE direction.
9.3
While holding the PST and closure with one hand, unwind the core by
pulling on the core tail with the other hand in an upward and outward
COUNTERCLOCKWISE direction until approximately 0.5"(13 mm)
of the PST is shrunk onto the closure.
9.4
Push PST towards bottom of closure. This will invert the PST.
Note: Do not force the PST to slide on the closure during inversion.