background image

7

3.15 

Verify the 8 mm cleave length again by using the length 

gauge on the assembly base. The 8 mm cleave length is 

measured from the end of the 900 µm buffer to the end of 

the cleaved fiber. On semi-tight buffer fiber, the 250 µm 

coating may protrude 1 mm past the 900 µm semi-tight 

buffer. Re-strip, clean and cleave the fiber if necessary to 

meet length requirements.

3.16 

Open activation lever #3 and clamp #2 of angle cleaver. 
Dispose of fiber shard per company practice.

4.0   Fiber Insertion

4.1 

Slide the fiber holder’s guide funnel fully forward and close 

the funnel cover. An audible click can be heard. Check for 

proper cleave length again by inspecting the amount of fiber 

protruding beyond the funnel end of the holder. The amount 
of exposed fiber should be from 0 to 1 mm (0.04").

4.2  

Place fiber holder in the assembly tool base. 

4.3  

VERY SLOWLY slide the fiber holder towards the 

connector. A bow in the fiber is started once the white line on 

the fiber holder is even with the white line (BOW START) on 

the base. If a bow is not seen, strip, clean and cleave the fiber 

as shown in section 3 and try installation again.

Bow Start

Slide very slowly

Note:  See photo in 4.4 for more detail.

4.4  

If a bow is seen before the white line on the holder meets 

the white line on the base, then strip, clean, and cleave the 
fiber as shown in Section 3 and try again.

When white lines 
meet, Fiber Bow 
should start.

Summary of Contents for 8800 APC/AS

Page 1: ...October 2010 78 8140 1581 0 C 3M No Polish Connector 8800 APC AS SM SC APC Angle Splice 250 900 µm Instructions ...

Page 2: ...lush eyes with water while holding eyelids open and continue flushing for ten minutes Contact a physician Upon skin contact wash with soap and water Product Information Material Safety Data Sheet or 3M Company St Paul MN 55144 1000 651 733 1110 Operator 55 Bare Fiber Handling cCAUTION Cleaved glass fibers are sharp and can pierce the skin Use tweezers when handling shards and dispose of them prope...

Page 3: ...No Polish Connector Assembly Tool 8865 AT 3M Fiber Holder 3M Fiber Stripper 6365 KS Isopropyl Alcohol Fiber Shard Container Lint Free Cloths 1 3 For situations where a suitable work area is not available the case and plastic plate which are included in the 2565 kit can create a work surface The case can be set on level ground on a vehicle or hung by the hook and shoulder strap 1 4 Add one full bot...

Page 4: ... the connector body 2 3 Open the actuator button on the assembly tool base Insert connector into coupling in the tool with white actuation cap facing upwards pushing forward until it clicks 3 0 Fiber Preparation 3 1 Open all three angle cleaver clamps and levers 3 2 Carefully clean the cleaver clamps using a small brush 3 3 For 900 µm buffer fiber cut the buffer If the 900 µm slides easily from th...

Page 5: ...ete the installation Semi Tight Buffered Fibers 3 4 For all fibers strip the 900 µm and 250 µm coatings exposing glass for 1 67 to 1 77 42 5 mm to 45 mm 3 5 To verify the correct strip length use the white marks on the left side of the cleaver Align the coating edge to the left edge of the cleaver and the fiber tip should be between the two white lines 3 6 Clean fiber with alcohol and lint free cl...

Page 6: ...er holder The funnel cover will not close completely while in the cleaver Do not force or cover can break funnel cover 3 13 Depress cleave activation lever 3 and hold it down until Clamp 2 slide assembly has fully moved to the right indicating that the angle cleave is complete Note If fiber does not break immediately upon activation or it breaks so that the cleave length is not 8 mm then open clam...

Page 7: ... be heard Check for proper cleave length again by inspecting the amount of fiber protruding beyond the funnel end of the holder The amount of exposed fiber should be from 0 to 1 mm 0 04 4 2 Place fiber holder in the assembly tool base 4 3 VERY SLOWLY slide the fiber holder towards the connector A bow in the fiber is started once the white line on the fiber holder is even with the white line BOW ST...

Page 8: ...rform this step now Do not proceed to step 5 2 until testing is complete If re termination is required please skip to Section 6 3M No Polish Connector NPC Re termination 5 2 Press release lever to allow forward motion of funnel Push ears to move funnel forward and actuate buffer clamp 5 3 Open the clamp and lift the covers to release fiber 5 4 Slide fiber holder from actuation tool Optional 3M No ...

Page 9: ...s the cap popper into the NPC connector shell until the activation cap is depressed Remove fiber and insert connector with the actuation cap facing up in the coupling pushing forward until it clicks Follow steps 3 0 through 5 1 to re terminate the NPC connector 6 3 Upon verification that connector has been terminated satisfactorily slide the fiber holder up into the back of the boot Return to step...

Page 10: ...oduct or refund the purchase price of the 3M product Except where prohibited by law 3M will not be liable for any indirect special incidental or con sequential loss or damage arising from this 3M product regardless of the legal theory asserted 3 Communication Markets Division 6801 River Place Blvd Austin TX 78726 9000 1 800 426 8688 www 3MTelecommunications com Please Recycle Printed in USA 3M 201...

Reviews: