!!!!  Pinching the nosepiece using one hand may result in improper fit and less effective 
respirator performance.  Use two hands. 

6.  Perform a User Seal Check prior to each wearing (Fig. 6).  To check the respirator-to-face 

seal, place both hands completely over the respirator and exhale.  Be careful not to disturb the 
position of the respirator.  If air leaks around nose, readjust the nosepiece as described in step 
4.  If air leaks at the respirator edges, work the straps back along the sides of your head.  If 

If 

If 

If 

you CANNOT

you CANNOT

you CANNOT

you CANNOT    achieve a proper seal, DO NOT enter the contaminated area.  See your 

achieve a proper seal, DO NOT enter the contaminated area.  See your 

achieve a proper seal, DO NOT enter the contaminated area.  See your 

achieve a proper seal, DO NOT enter the contaminated area.  See your 

supervisor.

supervisor.

supervisor.

supervisor.    

 

Removal Instructions

Removal Instructions

Removal Instructions

Removal Instructions    

Cup the respirator in one hand to maintain position on face.  Pull bottom strap over your head.  
Still holding respirator in position, pull top strap over your head and remove respirator. 

 

NIOSH Approved: N95

NIOSH Approved: N95

NIOSH Approved: N95

NIOSH Approved: N95    

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.

At least 95% filtration efficiency against solid and liquid aerosols that do not contain oil.    

 

This respirator contains no components made from natural rubber latex. 

 

NIOSH TABLE PLACEHOLDER 

 

Below the above line is a placeholder for appropriate addresses and phone numbers depending 
on the country or region sold. 

FOR MORE INFORMATION

FOR MORE INFORMATION

FOR MORE INFORMATION

FOR MORE INFORMATION    
In United States, contact:

In United States, contact:

In United States, contact:

In United States, contact:    

Internet: www.3M.com/workersafety  

Technical Assistance: 1-800-243-4630 

 

For other 3M

For other 3M

For other 3M

For other 3M    products:

products:

products:

products: 

1-800-3M-HELPS or 
1-651-737-6501 

 

 

 

 

 

 

 

 

3M 

3M 

3M 

3M Personal 

Personal 

Personal 

Personal Safety Division

Safety Division

Safety Division

Safety Division    

  

 

 

 

3M Center, Building 0235-02-W-70 

St. Paul, MN 55144-1000 

©3M 2019 All rights reserved 

 

 

 

 

38-xxxx-xxxx-x 

3M PSD products are occupational use only.                                      98-0060-0030-2/1

 

Summary of Contents for 8864

Page 1: ...64 8864 8864 8864 Particulate Respirator User Instructions Particulate Respirator User Instructions Particulate Respirator User Instructions Particulate Respirator User Instructions Initials Initials Initials Initials Date Date Date Date Comments Comments Comments Comments PSS 6 5 19 Initial User Instructions ...

Page 2: ...pirator N95 Particulate Respirator N95 User Instructions IMPORTANT Keep these User Instructions for reference UI UI UI UI 98 98 98 98 0060 0060 0060 0060 0030 0030 0030 0030 2 2 2 2 1 1 1 1 doc doc doc doc 6 5 19 6 5 19 6 5 19 6 5 19 38 38 38 38 xxxx xxxx xxxx xxxx xxxx xxxx xxxx xxxx x x x x ...

Page 3: ...t exceed either 10 times the occupational exposure limit or applicable government regulations whichever is lower In the U S do not use when OSHA substance specific standards such as those for arsenic cadmium lead in the construction industry or 4 4 methylene dianiline MDA specify other types of respiratory protection This respirator does not supply oxygen Biological Particles Biological Particles ...

Page 4: ... to life and health are unknown or when concentrations exceed 10 times the permissible exposure limit PEL or according to specific OSHA standards or applicable government regulations whichever is lower 3 Do not alter abuse or misuse this respirator 4 Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the sealing surface of the respirator 5...

Page 5: ...e respirator is packaged with the covered metal nosepiece slightly bent You may need to straighten with your hands before positioning the respirator 2 Pull the bottom strap over your head and position it around the neck below the ears Fig 2 3 Pull the top strap over your head resting it high at the top of your head Fig 3 4 Adjust for a comfortable fit by pulling bottom edge under chin while holdin...

Page 6: ...espirator NIOSH Approved N95 NIOSH Approved N95 NIOSH Approved N95 NIOSH Approved N95 At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil At least 95 filtration efficiency against solid and liquid aerosols that do not contain oil At least 95 filtration efficiency agai...