IMPORTANT SAFEGUARDS

When using your overhead projection equipment,
basic safety precautions should always be
followed, including the following:
1.

Read and understand all instructions
before using. Pay particular attention to
areas where this symbol
 

!

 is shown.

2.

Close supervision is necessary when any
appliance is used by or near children. Do not
leave appliance unattended while in use.

!

3.

Care must be taken as burns can occur from
touching hot parts.

4.

Do not operate appliance with a damaged
cord or if the appliance has been dropped or
damaged until it has been examined by a
qualified serviceman.

!

5.

Position the cord so that it will not be tripped
over, pulled, or contact hot surfaces.

6.

If an extension cord is necessary, a cord with
a current rating at least equal to that of the
appliance should be used. Cords rated for
less amperage than the appliance may
overheat.

7.

Always unplug appliance from electrical outlet
before cleaning and servicing and when not in
use. Never yank cord to pull plug from outlet.
Grasp plug and pull to disconnect.

!

8.

Let appliance cool completely before putting
away or when replacing lamp.

9.

To reduce the risk of electric shock, do not
immerse this appliance in water or other
liquids.

10. To reduce the risk of electric shock, do not

disassemble this appliance, but take it to a
qualified technician when service or repair
work is required. Incorrect reassembling can
cause electric shock when the appliance is
used subsequently.

11. The use of an accessory attachment not

recommended by the manufacturer may
cause a risk of fire, electric shock, or injury to
persons.

12. Do not overload accessory circuit.
13. Connect this appliance to a grounded outlet.
14. Disconnect this unit from its source of supply

before replacing the projection lamp.

!

15. This unit is equipped with optical lenses and

should not be exposed to direct sunlight.

16. Keep ventilation openings free of any

obstructions.

17. This unit is connected by a special cable that,

if it is damaged, has to be replaced by the
same type of cable. This cable can be
ordered from your local 3M dealer and has to
be installed by a qualified serviceman.

SAVE THESE INSTRUCTIONS

The information contained in this manual will help
you operate and maintain your overhead
projector.

Summary of Contents for 9700

Page 1: ...tprojektor Bedienungsanleitung Retroproyector Manual del operador Lavagna Luminosa Manuale d Uso Overhead Prosjekt r Bruksanvisning Overheadprojector Handleiding Retroprojector Manual do usu rio Overh...

Page 2: ...ador Esperamos que disfrute al usar este producto de alto rendimiento en sus reuni nes cursillos y demostraciones ITALIANO Vi ringraziamo di aver scelto una lavagna luminosa della 3M Questo apparecchi...

Page 3: ...7 cm x 177 cm 213 cm x 213 cm 243 cm x 243 cm 50I x 50I 60I x 60I 70I x 70I 84I x 84I 96I x 96I 9700 EVD F 342 mm 187 cm 74I 217 cm 86I 248 cm 98I 291 cm 114I 327 cm 129I 9700 EVD F 342 mm x 50I x 60I...

Page 4: ...k cord to pull plug from outlet Grasp plug and pull to disconnect 8 Let appliance cool completely before putting away or when replacing lamp 9 To reduce the risk of electric shock do not immerse this...

Page 5: ...ernal machine characteristics for the 9700 Part Identification List 1 Open Projection Head 2 Projection Mirror 3 Mirror Lift Tab 4 Triplet Lens 5 Flip In Magnifier Optional Accessory 6 Head Release Bu...

Page 6: ...Post will lock into place 6 Push head release button and rotate head 90_ until it locks into place 7 Grasp mirror lift tab and raise projection mirror Fold Down Projector 1 Unplug power cord from elec...

Page 7: ...r film transparency on stage glass 4 8 Set High Low lamp setting to desired position See High Low Lamp Setting below 9 Rotate focus knob 5 for clearest image Caution The glass and metal frame on the f...

Page 8: ...w lamp fully and squarely into socket For EVD lamp do not touch bulb glass with fingers Close condenser lens frame and secure with bracket 5 Close stage cover and plug in power cord Color Tuning Rotat...

Page 9: ...lass and Lenses Use 3M Overhead Cleaner 676 to remove surface dirt from the stage glass and projector lens Caution Cleaning the underside of the stage glass or Fresnel lens is not recommended Improper...

Page 10: ...ssible electrical problem a Replace lamp again b If new lamp fails immediately you may have an electrical problem Call for service Short lamp life Lamps seem to fail before expected life span a Defect...

Page 11: ...o de vendas da 3M ou o fornecedor onde adquiriu o seu aparelho COUNTRY COMPANY NAME ADDRESS LOCATION Austria 3M stereich Ges m b H Brunner Fieldstra e 63 A 2380 Perchtoldsdorf Belgium 3M Belgium N V...

Page 12: ...is marked with the letter L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black Replacement fuses of 10 amp should be...

Page 13: ...TA 300 Carro deluxe XX 0034 1164 0 RS 7110 70 0705 6877 2 DY 0210 0010 3 EVD 78 6969 8054 5 HA 5706 Lamp Lampe Lampe Bombilla Lampada Lampe Lamp L mpada EVD 9700 Overhead Cleaner Nettoyant pour r trop...

Page 14: ...Visual Systems Division 6801 River Place Boulevard Austin Texas 78726 9000 Printed in U S A E3M 6 96 78 6970 6359 8 Rev C...