background image

3M Fall Protection 

     

    

 

 

                                        

 

 

Inspection Notice 

IMMEDIATE ACTION REQUIRED 

3M™ DBI

-

SALA® ExoFit NEX™ Harnesses

 

 

3M  Fall  Protection  has  learned  of  the  possibility  of  a  manufacturing  defect  in  a  dorsal  d-ring 

utilized  in  ExoFit  NEX™  harnesses 

manufactured between January 2016 and December 2018. Although there have been no reported incidents involving this condition, 
a dorsal d-ring with this defect will not support the load in a fall arrest event which could result in serious injury or death. Harnesses 
manufactured only within this date range require immediate inspection for lot number 09P1 stamped into a dorsal d-ring.  We believe 
that only one harness was manufactured with a defective D-ring, but we urge inspection of all potentially affected harnesses out of 
an abundance of caution in the interests of worker safety. 

End Users

: Upon receipt of this Notice, immediately inspect your harness following the steps below: 

Step 1:  Locate the label pack on the harness to identify the manufacturing date.  If the harness has a manufacturing date of 16/01 
(2016, January) through the end of  18/12 (2018, December), continue to step 2.  If the harness is not in this range, the unit is not 
impacted by this notice. If the harness is within this date range, continue to step 2. 

Step 2: Locate the D-ring on the back of the harness to inspect for a stamped lot date of 09P1.  If you find a D-ring with code 09P1 and 
the harness has a manufactured date within the affected date range, take the harness out of service immediately. If the D-ring is not 
stamped with code 09P1, you may continue using your harness. 

Please note that  both the manufactured date  range  (2016, January through 2018, December) on the harness label  AND the  lot 
number code  09P1 stamped on the  D-ring  must be present  on the same harness  for  the harness to be considered suspect  and 
removed from service

.  

All other harness/d-ring combinations are acceptable for use.

 

 

 

 

 
 
 
 
 
 

 
 
 
Affected  Part  Numbers: 

https://multimedia.3m.com/mws/media/1675006O/3m-dbi-sala-exofit-nex-harnesses-inspection-notice-

part-numbers.xlsx

 

 
End-users:  

If you find an affected harness, take the unit out of service immediately.  You can contact us at 3M Customer Service at 

(833) 638-2697 or at 3musfpserviceaction@mmm.com to return your harness and a replacement harness will be provided free of 
charge. 

 
Distributors

:  Please  contact  our  Customer  Service  department  at  (833)  638-2697  or  email  at 

3musfpserviceaction@mmm.com

  to 

obtain a listing of  harnesses sold to you with the affected  manufacturing date range. If after inspection you discover you have an 
affected product in stock, please return the harnesses to 3M Fall Protection immediately for replacement.  Please immediately forward 
this Inspection Notice to any of your customers who have purchased ExoFit NEX product within the affected manufacturing date range 
from you and provide any assistance requested by your customers to complete the process. 
 
3M remains committed to providing quality products and services to our customers. We apologize for any inconvenience that this 
situation may cause you or your customers.  We appreciate your continued support of 3M Fall Protection products and services. 
3M Fall Protection 

 

 

 

 

 

 

 

 

 

 

April 16

th

, 2019

Step 1 Manufacture Date on Harness Shown in Red Circle 

 must 

be between 16/01 (2016, January) and 18/12 (2018, December)   

Step 2 Lot Code Stamp Location on D-ring 

 lot 

code must be (09P1) 

Reviews: