7
1.0 APPLICATIONS
1.1 PURPOSE:
Capital Safety Self-Retracting Lanyards (SRLs) are designed to be a component in a personal
fall arrest system (PFAS). Figure 1 illustrates SRLs covered by this instruction manual and their typical
applications. They may be used in most situations where a combination of worker mobility and fall protection
is required (i.e. inspection work, general construction, maintenance work, oil production, confined space
work, etc.). Some SRL models are equipped with integral rescue capability in the form of an RSQ™ Fall
Arrest/Descent Selection Knob or a 3-Way Retrieval Hand Crank.
1.2 STANDARDS:
Your SRL conforms to the national or regional standard(s) identified on the front cover of
these instructions.
1.3 TRAINING:
This equipment is intended to be used by persons trained in its correct application and use. It is the
responsibility of the user to assure they are familiar with these instructions and are trained in the correct care and use
of this equipment. Users must also be aware of the operating characteristics, application limits, and the consequences of
improper use.
1.4 LIMITATIONS:
Always consider the following limitations and requirements when installing or using this
equipment:
•
Capacity:
This SRL has been compliance tested for use by one person with a combined weight (clothing,
tools, etc.) from 130 lbs (59 kg) to 310 lbs (141 kg).
1
Make sure all of the components in your system
are rated to a capacity appropriate to your application.
•
Anchorage:
Anchorage structure for the SRL must be capable of supporting loads up to 10 kN (2,248
lbs). Anchor devices must conform to EN795.
•
Locking Speed:
Situations which do not allow for an unobstructed fall path should be avoided. Working
in confined or cramped spaces may not allow the body to reach sufficient speed to cause the SRL to lock
if a fall occurs. Working on slowly shifting material, such as sand or grain,may not allow enough speed
buildup to cause the SRL to lock. A clear path is required to assure positive locking of the SRL.
•
Free fall:
When used correctly, SRLs will limit the free fall distance to 61 cm (2 ft). To avoid increased fall
distances, do not work above the anchorage level.
Do not lengthen SRLs by connecting a lanyard or
similar component without consulting Capital Safety.
Never clamp, knot, or prevent the lifeline
from retracting or being taut. Avoid slack line.
•
Swing Falls:
Swing Falls occur when the anchorage point is not directly above the point where a fall
occurs. The force of striking an object in a swing fall may cause serious injury (see Figure 3A). Minimize
swing falls by working as directly below the anchorage point as possible.
•
Fall Clearance:
Figure 3B illustrates Fall Clearance. SRL Fall Arrest Systems should have a minimum Fall
Clearance of 2 m (6 ft) for falls from a standing position where the SRL is anchored directly overhead. Falls
from a kneeling or crouching position will require an additional 1 m (3 ft) of Fall Clearance. In a swing fall
situation, the total vertical fall distance will be greater than if the user had fallen directly below the
anchorage point and may require additional Fall Clearance. The table in Figure 3 provides the minimum
vertical Fall Clearance needed below the working level of the SRL user where added Swing Fall distance
is within the recommended range of use.
•
Hazards:
Use of this equipment in areas where surrounding hazards exist may require additional precautions to
reduce the possibility of injury to the user or damage to the equipment. Hazards may include, but are not limited
to: high heat, caustic chemicals, corrosive environments, high voltage power lines, explosive or toxic gases, moving
machinery, or overhead materials that may fall and contact the user or fall arrest system. Avoid working where
your lifeline may cross or tangle with that of another worker. Avoid working where an object may fall and strike the
lifeline; resulting in loss of balance or damage to the lifeline. Do not allow the lifeline to pass under arms or between
legs.
•
Sharp Edges:
Avoid working where the lifeline will be in contact with or abrade against unprotected
sharp edges. Where contact with a sharp edge is unavoidable, cover the edge with a protective material.
2.0 USE
2.1 RESCUE PLAN:
When using this equipment, the employer must have a rescue plan and the means at hand
to implement it and communicate that plan to users, authorized persons, and rescuers.
1 Capacity:
While CE SRLs have a Maximum Capacity of 141 kg (310 lbs), SRLs with 3-Way Retrieval are rated for a Maximum Lifting Load of 135 kg (298 lbs).
Summary of Contents for DBI SALA Sealed-Blok 3400828
Page 3: ...3 6 7 A B A B A B C A C B C D C B A B C D E...
Page 4: ...4 8 1 2 3...
Page 5: ...5 9 1 2 3 4 5A 5B 10 11 12 13 B B A A C C A D C B A 14 A B C D...
Page 67: ...67 5 3 Capital Safety 5 4 Sealed Blok DBI SALA 6 0 6 1 6 2 6 3...
Page 68: ...68 2 SRL 11 A 12 13 A B C D 25 1 14 A B C 34 75...
Page 78: ......