7
DIDF260-CL System Pre-Start-Up procedure:
1. Turn ice water inlet valve ON.
2. Remove trapped air in the ice line by opening and closing valve downstream.
3. Turn beverage water inlet valve ON.
4. Remove trap air in the beverage line by opening and closing the beverage outlet venting valve.
5. Flush system in accordance with the cartridge Performance Data Sheet.
Troubleshooting
Problem
Potential Cause(s)
Suggested Solution
No water flow through system
Inlet valve closed
Cartridges clogged
Check shut-off valve position
Replace cartridges
Not enough water to the
downstream application(s)
Low incoming water pressure
Cartridges clogged
Check source
Replace cartridges
Short filter life
Temporarily dirty water
Change cartridges or install an
additional upstream prefilter