Operation
Section 1
Page 50
Ringers
RED to RING
BLACK to TIP
GREEN to GROUND
Hookup:
R
B
G
About the Ringers Test
Use the RINGERS key to count the ringer equivalences
and display bell circuit wiring configuration at the
subscriber premises, based on a type 5200 telephone
having a 1.0 ringer equivalence, and to check for the
presence of a maintenance test unit (MTU) at the
subscriber premises.
To count ringers on a pair, connect at the subscriber
protector, remove cable plant and press the RINGERS
key. The 900/900M Series test set shows ringer wire
configuration as bridged, wired tip, or wired ring.
Exceptions to these wiring configurations are numerous
and we do not attempt to list them.
Note: Resistance faults, as well as capacitive imbalance, can
cause false readings such as “RESISTANCE TOO LOW” or
“INVALID RINGERS HOOKUP.”
Caution
If hazardous voltage warnings are displayed when the test set is
switched on or reset (or at any time during the testing
procedure) follow standard procedures for de-energizing and
discharging cables.