Care & Maintenance
Section 4
Page 79
Page 79
Step 5
Replace the
battery cover. Turn the unit
on. The message “
PLEASE
IDENTIFY BATTERIES
USED
” appears. Press the
(pound key) or
(star
key) to identify battery type,
then press the
AUTO CAL
key and run self calibration.
Note:
When installing new rechargeable batteries, or
to compensate for weak rechargeable batteries, use
the internal battery charger to overcharge the cells
(18 hours, maximum).
Follow the instructions on the
display to connect the leads to an external 12-volt source,
such as a Dynatel Model 1658 or 1678 battery charger kit.
Turn the unit on. Press the AUTO-CAL key. Use the
arrow keys to select the “CHARGE BATTERY”
function, and press the
(star key). Press the
(pound key) to select the overcharge function, and
press the
(star key) to activate the charging
process. The unit turns off automatically when
charging is complete.
2.
BATTERY MAINTENANCE
2.1
Rechargeable batteries last longer when properly
recharged. The unit keeps track of power usage,
displays an estimate of the battery charge, and displays a
message prompting you to charge the batteries at the
correct time.