13
78-8140-2401-0-B
8.13 Install the cable clamp by positioning over the
cable set.
Note: If differently-sized cables are used,v ensure the
cable is placed into the correct cable clamp shell
set in bottom housing.
8.14 Start the center clamp screw (longer screw) and
lightly tighten. Evenly tighten the two outer
screws (shorter screws) along with the center
screw by alternating between. Torque all three
clamp screws to 30 in.-lbs.
8.15 Place top half of the 3M
™
Double Cable Entry Port ECAM-27MM-D. Align top and bottom housings
and squeeze the halves together evenly.
CAUTION
Do not pinch fibers between halves.
8.16 Start all three of the screws. Then evenly tighten
the three clamp screws by alternating between
screws.
B
A
A