7
78-8140-2401-0-B
6.0 Cable Gauge Decal
Use the supplied cable gauge to determine the proper
cable clamp shells, washers and correct amount of
mastic needed to build a sealing collar.
6.1
Place the cable gauge decal on the cable as shown below. Be sure to place decal in-line with the cable.
Correct
Incorrect
6.2
Read between the arrows on the decal to
determine the amount of mastic, clamp shells
and washer needed to properly assemble
the 3M
™
Double Cable Entry Port ECAM-
27MM-D. This information can be recorded in
the log at the bottom of this page.
Note: If the arrows on the decal point at the line
between two different sizes, use what is listed in
the box below the line. Also note that no clamp
shells are required if gauge indicates ‘NONE’ in
the shell column.
Note: If two differently-sized cables are used repeat this
procedure for the second cable and record this
information in the Cable 2 section of the log.
LOG
Mastic Cut
Length
Cable Clamp
Shells
Washers
Cable 1
Cable 2
Note: To plug an unused port in the 27-mm Double ECAM assembly, use 14.0 inches (356 mm) of mastic rolled
into a cylinder.