SAFETY INFORMATION
EXPLANATION OF SIGNAL WORD CONSEQUENCES
CAUTION
IMPORTANT NOTES
Read, understand, and follow all safety information contained in these instructions
prior to installation and use of the Filtrete™ Standard and Professional Water
Filtration Systems. Retain these instructions for future reference.
Intended use:
The Filtrete Standard and Professional Water Filtration Systems are intended for use in
fi
ltering
drinking water in homes and have not been evaluated for other uses. These systems are
typically installed under a sink where
fi
ltered drinking water is desired, and must be installed,
operated and maintained as speci
fi
ed in the installation and use instructions.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided,
could result in death or serious injury and/or property damage.
Indicates a potentially hazardous situation, which, if not avoided,
may result in property damage.
To reduce the risk associated with ingestion of contaminants:
•
Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system
. Only the Professional Water Filtration
System (3US-PS01) is certi
fi
ed for cyst reduction and may be used on disinfected water
that may contain
fi
lterable cysts. EPA Establishment #070595-CT-001.
To reduce the risk associated with a hazardous voltage:
• Do not install near electric wiring or piping which may be in the path of a drilling tool when
selecting the position to mount the
fi
lter bracket.
To reduce the risk associated with property damage due to water leakage:
•
Read and follow
Use Instructions before installation and use of this system;
• Comply with all state or local plumbing codes;
• Install on cold water lines only;
•
Protect
fi
lter from freezing
. Drain
fi
lter when room temperature drops below 40°F (4.4°C);
•
Do not
install if water pressure exceeds 125 psi (862 kPa). If your water pressure exceeds
80 psi, you must install a pressure limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure;
•
Do not
install where water hammer conditions may occur. If water hammer conditions
exist you must install a water hammer arrester. Contact a plumbing professional if you are
uncertain how to check for this condition;
•
Do not
install on hot water supply lines. The maximum operating water temperature of
this
fi
lter system is 100°F (38°C);
• The
disposable
fi
lter cartridge
must
be replaced every six months, at the rated capacity
or if a noticeable reduction in
fl
ow rate occurs.
•
Do not
install near water pipes which will be in path of a drilling tool when selecting the
position to mount the bracket;
• Mount
fi
lter in such a position as to prevent it from being struck by other items used in the
area of installation (waste baskets, etc.);
• Ensure all tubing and
fi
ttings are secure and free of leaks;
•
Do not
install in direct sunlight.
• SHUT OFF FUEL SUPPLY TO WATER HEATER after water is shut off.
• Failure to follow instructions will void warranty.
• Allow a minimum of 2” (5 cm) clear space under
fi
lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
WARNING
WARNING