3M™ MicroTouch™ Controller EX Serial Reference Guide
11
3M Touch Systems, Inc. Proprietary Information -- 29087v03
EX122 Sensor Cable Connections
The sensor cable has a 12-pin (2 x 6) dual row female connector that plugs into the
controller. Table 2 describes the pins on this connector. The sensor connector always
exits towards the serial cable.
Table 2 Sensor Cable Connector for EX122 Controllers
Pin Wire Color
Description
1
———
NOVRAM interface
2
———
NOVRAM interface
3
———
NOVRAM interface
4
——— +5
VDC
5
6
7
Gray
Green
Orange
Power supply ground
Chassis (earth) ground
+12V input
8 Brown
Cable
shield/drain wire
Connects to the flex tail shield, which must not be grounded
because the EX122 drives the flex tail shield with an AC
waveform.
9
10
11
12
White
Red
Black
Blue
Upper right (UR) corner
Lower right (LR) corner
Upper left (UL) corner
Lower left (LL) corner
EX112 Sensor Cable Connections
The sensor cable has a 5-pin single row locking female connector that plugs into the
controller. Table 3 describes the pins on this connector.
Table 3 Sensor Cable Connector for EX112 Controllers
Pin Wire Color
Description
1
Upper left (UL) corner
2
Upper right (UR) corner
3 Cable
shield/drain
wire
Connects to the flex tail shield, which must
not
be grounded
because the EX112 drives the flex tail shield with an AC
waveform.
4
Lower right (LR) corner
5
Lower left (LL) corner
Mounting the Controller
The cased controller is mounted externally. The uncased controller is mounted internally.
Choose a convenient spot away from high-voltage, high power cables and electronics.
Use 4-40 plastic screws to mount the cased controller to eliminate possible ESD input
path. Metal or plastic screws can be used on the 2x3 board if the green ground wire is