22
3M™ MicroTouch™ Controller EX Serial Reference Guide
3M Touch Systems, Inc. Proprietary Information -- 29087v03
Description:
Initiates an interactive 2-point calibration.
During the calibration process, you define the active area of the sensor by mapping
locations to an absolute X/Y coordinate system. You touch two
target areas
on the
sensor. Touching the target areas sends the X/Y coordinates for those touch points to the
controller. The controller calculates all other touch points based on these two points.
The Calibrate Extended command sets the calibration targets (points) inward from the
corner of the video image. Setting the targets inward makes the calibration process easier
and more accurate.
Guidelines for Calibrate Extended
Here are several guidelines for using the Calibrate Extended command:
The controller uses the data immediately before liftoff to register a calibration touch.
Therefore, you can touch the sensor, move your finger to the target, hold for a few
seconds, and then lift off. Instructing users to touch this way results in a more
accurate calibration.
The controller stores the data in non-volatile memory (NOVRAM). Therefore, you
do not have to calibrate the sensor each time you power on the system. You should,
however, recalibrate the sensor any time the video display changes size or resolution.
You can restart calibration at any time during this sequence by issuing a Reset
command and reissuing a CX command.