12
C. Poured Slab Mount Installation of 4084 and 4086
Cabinets
NOTE: The MS
2
4056 Mounting Ring Kit is needed for
this installation. See Figure 19.
1. Ground Preparation
a. Excavate slab site to a depth of 300 mm (12 in.)
below ground level allowing for slab dimensions of
1.8 m (6 ft.) x 1.8 m (6 ft.). See Figure 20.
b. Set forms for a 1.8 m (6 ft.) x 1.8 m (6 ft.) x 100 mm
(4 in.) slab.
NOTE: Construct forms so that slope of slab from center
is at the rate of 20 mm per running meter (1 /4 in. per
running foot).
c. Fill excavation with pea gravel to within 100 mm
(4 in.) of ground level. See Figure 21.
d. Attach Concrete Inserts and Support Legs to the
Mounting Ring with the M12 x 25.4 mm (1 /2" x 1")
bolts provided. See Figure 22.
e. Nail wood stakes to Mounting Ring for ease in
leveling. Center Mounting Ring in slab excavation
and level. See Figure 23. (Nails must be cut off when
wooden stakes are removed.)
f. Place concrete reinforcing rods or wire mesh in
slab area.
g. Pour and finish slab.
Figure 19.
Figure 20.
Figure 21.
Figure 22.
Figure 23.