22
b. Cabinet Venting
To close vents and eliminate air circulation, turn blank side
of plastic vent toward louver plate.
To open vents for maximum air circulation, insert plastic
vent with screened side toward louver plate.
c. MS
2
4064 Terminal Block Bracket
This Bracket will accommodate two 3-pair protected or
unprotected terminal blocks in the MS
2
4065 Cross-Connect
Cabinet. Service Wires may be bonded and secured directly
to The front of the Bracket per system practice.
1. Loosen both Bond Bar Fastening Bolts using M12
(7/16") wrench.
2. Install Terminal Block Bracket as shown in Figure 46.
3. Retighten Bolts.
2. MS
2
Pole-Mount Cabinets
a. Feeder and Distribution Module Location in 300 pr.
Pole-Mount Cabinet. See Figure 49.
NOTE: Feeder Module locations are interchangeable
from top to bottom. Figure 49 shows Distribution Modules
on top and Feeder Modules on bottom. Feeder and
Distribution should be separated by the Wire Run Guide.
b. Feeder and Distribution Module Location in 4094
and 4095 Pole Cabinets. See Figure 50.
Figure 48.
Figure 49.
Figure 50.