background image

(English) 

1

W   

 WARNING

This respirator helps protect against certain particles. 

Misuse may result in sickness or death. 

For correct use, consult supervisor 

and these 

User Instructions

, or call 3M in U.S.A., 1-800-247-3941. In Canada, call Technical Service at 1-800-267-4414. In Mexico, call 

01-800-712-0646.

IMPORTANT

Before use, wearer must read and understand these 

User Instructions

. Keep insert for reference.

Use For

Particles such as those from processing minerals, coal, iron ore, cotton, flour, and certain other substances. Liquid- or oil-based particles from sprays 

that do not also emit harmful vapors. Nuisance-level acid gases such as sulfur dioxide, hydrogen fluoride and/or chlorine. (Nuisance-level acid gas 

refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits, whichever is lower.) Follow all applicable local 

regulations. For additional information on 3M use recommendations for this class of respirator please consult the 3M Respirator Selection Guide found 

on the 3M Personal Safety Division (PSD) website at www.3M.com/respiratorselector or call 1-800-243-4630 in U.S.A. In Canada, call 1-800 267-4414.

Do Not Use For

Do not use for gases, asbestos or sandblasting; particulate concentrations that exceed either 10 times the occupational exposure limit or applicable 

government regulations, whichever is lower. Do not use for organic vapors, including those present in paint spraying operations, when concentrations 

exceed the US OSHA PEL or applicable government occupational exposure limits, whichever is lower. In the U.S., do not use when OSHA substance 

specific standards, such as those for arsenic, cadmium, lead in the construction industry, or 4,4’-methylene dianiline (MDA), specify other types of 

respiratory protection. This respirator does not supply oxygen.

Biological Particles

This respirator can help reduce inhalation exposures to certain airborne biological particles (e.g. mold, 

Bacillus anthracis

Mycobacterium tuberculosis

etc.) but cannot eliminate the risk of contracting infection, illness or disease. OSHA and other government agencies have not established safe 

exposure limits for these contaminants.

Use Instructions

1.  Failure to follow all instructions and limitations on the use of this respirator and/or failure to wear this respirator during all times of exposure can 

reduce respirator effectiveness and 

may result in sickness or death.

2.  Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the requirements of 

OSHA 29 CFR 1910.134 such as training and fit testing and applicable OSHA substance specific standards. In Canada, CSA standard Z94.4-93 

requirements must be met and/or requirements of the applicable jurisdiction, as appropriate.

3.  The particles which can be dangerous to your health include those so small that you cannot see them.
4.  Leave the contaminated area immediately and contact supervisor if dizziness, irritation, or other distress occurs.
5.  Store the respirator away from contaminated areas when not in use.
6.  Inspect each respirator before each use to ensure that it is in good operating condition. Examine all the respirator parts for signs of damage 

including the two headbands, attachment points and noseclip. The respirator should be disposed of immediately upon observation of damaged or 

missing parts. Filtering facepieces are to be inspected prior to each use to assure there are no holes in the breathing zone other than the punctures 

around staples and no damage has occurred. Enlarged holes resulting from ripped or torn filter material around staple punctures are considered 

damage. Immediately replace respirator if damaged. Staple perforations do not affect NIOSH approval.

7.  Dispose of used product in accordance with applicable regulations.

Use Limitations

1.  This respirator does not supply oxygen. Do not use in atmospheres containing less than 19.5% oxygen.
2.  Do not use when concentrations of contaminants are immediately dangerous to life and health, are unknown or when  concentrations exceed 10 

times the permissible exposure limit (PEL) or according to specific OSHA standards or  applicable government regulations, whichever is lower. Do 

not use when acid gas concentrations exceed the OSHA  PEL or other applicable government occupational exposure limits, whichever is lower.

3.  Do not alter, abuse or misuse this respirator.
4.  Do not use with beards or other facial hair or other conditions that prevent a good seal between the face and the edge of the respirator.
5.  Respirators can help protect your lungs against certain airborne contaminants, however, they will not prevent entry through other routes such as 

the skin, which would require additional personal protective equipment (PPE).

6.  This respirator is designed for occupational/professional use by adults who are properly trained in their use and limitations. This respirator is not 

designed to be used by children.

7.  Individuals with a compromised respiratory system, such as asthma or emphysema, should consult a physician and complete a medical evaluation 

prior to use.

Particulate Respirator R95

3

User Instructions

8576

Summary of Contents for P95

Page 1: ...vel acid gas refers to concentrations not exceeding OSHA PEL or applicable government occupational exposure limits whichever is lower Recommandé par 3M contre les concentrations nuisibles de gaz acides Par concentrations nuisibles de gaz acides on entend les concentrations inférieures à la limite d exposition admissible de l Occupational Safety and Health Administration OSHA des États Unis É U ou ...

Page 2: ...rotection program must be implemented meeting all the requirements of OSHA 29 CFR 1910 134 such as training and fit testing and applicable OSHA substance specific standards In Canada CSA standard Z94 4 93 requirements must be met and or requirements of the applicable jurisdiction as appropriate 3 The particles which can be dangerous to your health include those so small that you cannot see them 4 ...

Page 3: ...3M products 1 800 3M HELPS or 1 651 737 6501 RENSEIGNEMENTS SUPPLÉMENTAIRES Aux États Unis Internet www 3m com workersafety Assistance technique 1 800 243 4630 Autres produits 3M 1 800 364 3577 ou 1 651 737 6501 Fig 1 Fig 2 Fig 3 Fig 4 Fitting Instructions Must be followed each time respirator is worn 1 Cup the respirator in your hand with the nosepiece at your fingertips allowing the headbands to...

Page 4: ...ed by regulatory standards J Failure to properly use and maintain this product could result in injury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instruc...

Page 5: ...ules biologiques en suspension dans l air p ex moisissures bacille du charbon bacille de Koch etc mais il n élimine pas le risque de contracter une infection ou une maladie L OSHA et d autres organismes gouvernementaux n ont pas établi de limites d exposition sécuritaires pour ces contaminants Directives d utilisation 1 Tout manquement aux directives et aux restrictions relatives à l utilisation d...

Page 6: ...irectives d utilisation précisées Si l on ne peut obtenir un ajustement parfaitement étanche ne pas pénétrer dans la zone contaminée Consulter son superviseur Fin de la durée de conservation Utiliser le respirateur avant la date de péremption indiquée sur l emballage 86 F 30 C 4 F 20 C Plage de températures d entreposage 20 C à 30 C 4 F à 86 F 80 Humidité relative maximale pour l entreposage 80 Du...

Page 7: ...FILTRATION FACIALE COMPOSANTS DES RESPIRATEURS 3M St Paul Minnesota USA 1 800 243 4630 A Ne pas utiliser dans les endroits où le taux d oxygène est inférieur à 19 5 B Ne pas utiliser lorsque l atmosphère présente un danger immédiat pour la vie ou pour la santé C Do not exceed maximum use concentrations established by regulatory standards J L utilisation et l entretien inadéquats de ce respirateur ...

Page 8: ... tiempo de exposición se puede reducir su efectividad y causar enfermedades o la muerte 2 Antes del uso ocupacional de este respirador se debe poner en práctica un programa de protección respiratoria estipulado por escrito que cumpla con todos los requisitos del Código de Reglamentos Federales 29 1910 134 de OSHA como por ejemplo aquellos que se refieren a la capacitación y pruebas de ajuste y las...

Page 9: ...o no ingrese al área contaminada Consulte a su supervisor Fin de la vida útil Use los respiradores antes de la fecha de vencimiento especificada en el empaque 86 F 30 C 4 F 20 C Rango de temperatura de almacenamiento Entre 20 C 4 F y 30 C 86 F 80 Humedad relativa máxima de almacenamiento 80 de humedad relativa HR Limitación del tiempo de uso 1 Si el respirador se daña ensucia o se hace difícil res...

Page 10: ... natural Aprobado por NIOSH N95 95 mínimo de eficiencia de filtración contra aerosoles sólidos y líquidos que no contienen aceite THIS RESPIRATOR IS APPROVED ONLY IN THE FOLLOWING CONFIGURATIONS FILTERING FACEPIECE TC PROTECTION1 8271 8576 8577 CAUTIONS AND LIMITATIONS2 84A 1166 P95 X X X ABCJMNOP 1 PROTECTION 2 CAUTIONS AND LIMITATIONS A Not for use in atmospheres containing less than 19 5 percen...

Page 11: ... 因職業需要在使用此呼吸防護具之前 必須擬定一個書面的呼吸保護計劃符合OSHA 29 CFR 1910 134的要求 如訓練和 密合度測試以及適用的 OSHA 指定標準 在加拿大 必須符合CSA Z94 4 93標準和適用的司法要求 3 可能對你的健康有害的粒狀物包括那些小到你看不到的顆粒 4 如果發生眩暈 刺激感或其他不適 立即離開污染區域並聯繫主管 5 不使用時 將呼吸防護具遠離污染區域 6 在每次使用前檢查呼吸防護具 確保其處於良好的運行狀態 檢查呼吸防護具的所有部位是否有損壞跡象 包括兩條頭 帶 部件接合點和鼻樑夾 觀察到損壞或零件缺失時 該呼吸防護具應該立即拋棄 在每次使用之前要檢查防護具 確保 呼吸區域沒有破孔 除了縫釘周圍的穿刺以外沒有其他損壞 在縫合釘周圍因拉伸引起濾材穿孔的擴大被視為損壞 如果 損壞 立即更換呼吸防護具 裝訂穿孔不影響NIOSH的批准 7 按照適用規定處理...

Page 12: ...棄呼吸防護具 2 如果僅在含有油性氣溶膠的環境中使用 請在使用 40 小時或 30 天後拋棄呼吸防護具 以較低者為準 Fig 1 Fig 2 Fig 3 Fig 4 配戴說明 每次佩戴口罩時必須遵守 1 將口罩放在手中 將鼻樑夾放在指尖處 讓頭帶自由懸掛在手下 圖1 2 將口罩置於下巴下方 鼻樑夾向上 將頂部的頭帶拉到頭頂並將底部頭帶拉到耳朵下方的頸部位置 圖2 3 將雙手食指及中指指尖放置在鼻樑夾頂部 順著鼻子的形狀向兩側按壓使口罩與鼻子的接觸部位密合 圖3 W 使用一隻手按壓鼻樑夾可能會導致不正確的密合度使得口罩之呼吸防護效能較差 使用雙手 4 每次佩戴口罩時須執行密合度檢點 將雙手在不影響口罩佩戴位置下蓋住口罩外側然後吸氣和呼氣 圖4 如果空氣在 鼻子周圍發生洩漏 請重新如第3步所述調整口罩之佩 戴 如果空氣在口罩邊緣發生洩漏 重新調整頭帶位置 如果調整 後狀況無法改善 不要進入作業...

Page 13: ...jury or death M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information on use and maintenance of these respirators P NI...

Reviews: