Do not use this product in uncured/wet concrete.
The precast concrete must have a compressive strength of at least 5,000 PSI
and the core wall must be 1-1/2” thick. ( See Dia. On next page )
Do not drill a hole closer then 6” from any corner or edge.
Drill a straight 3/4” diameter hole all the way through the core center utilizing
a rotary hammer drill and industrial grade SDS bit.
Only use industrial grade rotary hammer drills and drill bits.
DO NOT USE masonry drill bits.
Drill a 3/4” diameter hole .
Drill hole in the center of core hollow.
Never drill hole closer than 6” to any edge or corner.
Always inspect a previously drilled hole for deformation. Drill another proper hole if
needed.
Inspect the unit for damage each time you use it. If damage has occurred, dispose of unit.
Make sure the Toggle Bar is activated in the open position.
The Hole Plug must be seated in the concrete hole.
Never rely on a unit placed by unauthorized personnel.
Remove your unit at the end of each day.
6
Use For Fall Protection Only
SEE DIAGRAMS ON NEXT PAGE
INSTRUCTIONS FOR USE IN CONCRETE